五种旋转与往复镍钛系统在弯曲根管中运输与居中能力的微CT评价
研究用微CT评价5种不同冶金性能与表面处理的旋转/往复镍钛系统在25°–40°弯曲上颌磨牙近颊根管中的根管偏移与居中能力,每组12个根管。结果显示各系统在根尖三分之一表现相似,但Reciproc Blue整体及中、冠三分之一偏移显著大于其他系统,ProTaper Next居中能力优于Reciproc与Reciproc Blue。
要点
- 根尖三分之一各系统偏移与居中能力无显著差异。
- Reciproc Blue整体及中、冠部偏移显著大于其他系统。
- ProTaper Next居中能力优于Reciproc与Reciproc Blue。
核心结论
- 在根尖三分之一所有测试系统偏移与居中能力相似。
- 整体及中、冠三分之一结果显示往复系统偏移更大、预备居中性更差。
研究设计与样本
- 器械包括ProTaper Next、Reciproc Blue、Reciproc、TruNatomy与XP-endo Shaper。
- 预备前后行微CT扫描,在3个根管水平分析偏移与居中能力。
- 统计采用单因素方差分析及相应事后检验。
主要发现
- Reciproc Blue整体引起的根管偏移显著多于其他技术(P < .05)。
- 其他技术之间整体偏移无显著差异(P > .05)。
- ProTaper Next保持在根管中轴的能力显著优于Reciproc(P = .046)与Reciproc Blue(P = .017)。
- 根尖三分之一所有技术偏移与居中能力相似(P > .05)。
- 中、冠三分之一Reciproc Blue偏移显著大于其他技术(P < .05)。
关键数值与推荐
- 预备时每个根管使用5 mL 2.5%次氯酸钠。
- 最终冲洗方案为15% EDTA后再次次氯酸钠冲洗。
临床怎么用
- 在弯曲根管中、冠部预备时,往复系统(尤其Reciproc Blue)可能带来更大偏移,需权衡选择。
- 根尖三分之一各系统表现相近,可按其他临床因素选择器械。
局限性
- 结论受研究局限性约束,外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate the transportation and centering ability of 5 different rotary and reciprocating file systems with different metallurgical properties and surface treatments in curved root canals. METHODS: Fifty mesiobuccal round canals of upper molars with a curvature of 25°-40° were assigned to 5 experimental groups (n = 12) according to the instrumentation system used: ProTaper Next (Dentsply Sirona, York, PA), Reciproc Blue (RCB [VDW, Munich, Germany]), Reciproc (VDW), TruNatomy (TRN [Dentsply Sirona]), and XP-endo Shaper (FKG, La Chaux-de-Fonds, Switzerland). During instrumentation, 5 mL 2.5% sodium hypochlorite was used in each root canal. The final irrigation protocol included 15% EDTA followed by sodium hypochlorite irrigation. The micro-computed tomographic scanning of the samples was performed before and after instrumentation to analyze the transportation and centering ability at 3 canal levels. The results were analyzed with the 1-way analysis of variance test with the corresponding post hoc test. RESULTS: Overall, RCB caused significantly more canal transportation compared with the other techniques (P < .05). There were no significant differences between the other techniques (P > .05). ProTaper Next had a significantly better ability to stay within the central axis of the root canal compared with the Reciproc and RCB techniques (P = .046 and P = .017, respectively). In the apical third, all techniques caused similar apical transportation and centering ability (P > .05). In the middle and cervical parts of the canal, the RCB caused significantly greater canal transportation than the other techniques (P < .05). CONCLUSIONS: Under the limitations of this study, all tested techniques had similar transportation and centering abilities in the apical part of the canal. However, the overall results and those in the middle and coronal parts of the canal indicated that reciprocating instruments resulted in more canal transportation and less centered preparations.
引用
- Kabil E, Katić M, Anić I, et al. Micro-computed Evaluation of Canal Transportation and Centering Ability of 5 Rotary and Reciprocating Systems with Different Metallurgical Properties and Surface Treatments in Curved Root Canals. J Endod. 2020. PMID: 33217469. doi:10.1016/j.joen.2020.11.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。