文献速递牙体牙髓病

I型C形根管的消毒与成形:微计算机断层扫描与分子微生物学关联研究

Disinfecting and Shaping Type I C-shaped Root Canals: A Correlative Micro-computed Tomographic and Molecular Microbiology Study.
PubMed 文献 · J Endod · 2020-11-18

这项离体研究比较了两种预备方案在I型C形根管中的消毒和成形能力,均使用2.5%次氯酸钠冲洗。XP-endo Shaper联合XP-endo Finisher与BioRaCe联合H锉在成形参数上无显著差异,消毒效果也相似,但约半数病例在辅助步骤后仍可检出细菌。

要点

  • 两种预备方案在C形根管成形参数上无显著差异。
  • 辅助步骤可改善成形,但未能增强消毒效果。
  • 约半数病例在预备后仍可检出细菌。

核心结论

  • XP-endo Shaper和BioRaCe系统在C形根管中具有相似的消毒和成形能力。
  • H锉和XP-endo Finisher辅助步骤在改善成形方面效果相似,但不足以增强消毒。
  • 两组中约半数病例仍存在可检测的细菌。

研究设计与样本

  • 离体研究,选取具有I型C形根管的下颌第二磨牙,基于微计算机断层扫描分析配对匹配后分为两组。
  • 根管污染混合细菌培养后,分别使用XP-endo Shaper联合XP-endo Finisher(XP-E组)和BioRaCe联合H锉(BR-Hed组)预备,均使用2.5%次氯酸钠冲洗。
  • 在预备前、预备后和辅助步骤后分别进行微计算机断层扫描和根管内细菌采样。
  • 成形评估采用微计算机断层扫描成像,消毒评估采用定量聚合酶链反应。

主要发现

  • XP-E组(n=21)和BR-Hed组(n=23)在预备后和辅助步骤后的成形参数(根管体积、表面积、结构模型指数和预备壁)组间无显著差异(P > .05)。
  • 除XP-endo Finisher后结构模型指数变化无显著差异(P > .05)外,所有成形参数在每个预备步骤后均显著增加(P < .05)。
  • XP-E组(n=21)和BR-Hed组(n=22)的S2样本中分别有14例(66.7%)和10例(45.5%)仍可检出细菌。
  • XP-endo Finisher和H锉辅助步骤后,仍可检出细菌的样本分别为11例(52.4%)和10例(45.5%)。
  • 两组样本1的细菌计数在样本2和样本3中均显著下降(P < .01);样本2与样本3组内比较,H锉后计数减少66%,XP-endo Finisher后减少18%(两组P > .05)。

临床怎么用

  • 对于I型C形根管,XP-endo Shaper和BioRaCe系统均可用于成形和消毒,效果相当。
  • 辅助使用H锉或XP-endo Finisher可改善成形,但不应期望其显著增强消毒效果。
  • 预备后约半数病例仍残留可检测细菌,提示需考虑更有效的消毒策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This ex vivo study compared the disinfection and shaping abilities of 2 preparation protocols in C-shaped canals. METHODS: Mandibular second molars with type I C-shaped canals were pair matched based on micro-computed tomographic (micro-CT) analysis and distributed into 2 groups. The canals were contaminated with a mixed bacterial culture and prepared using 2 protocols, both with 2.5% sodium hypochlorite irrigation: XP-endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland) supplemented with XP-endo Finisher (FKG Dentaire) (XP-E) and BioRaCe (FKG Dentaire) supplemented with a Hedström file (Dentsply/Sirona, Tulsa, OK) (BR-Hed). Micro-CT scans and intracanal bacteriologic samples were taken before (scan #1 and sample 1) and after preparation (scan #2 and sample 2) and after the supplementary step (scan #3 and sample 3). Canal shaping was evaluated by micro-CT imaging, and disinfection was assessed by quantitative polymerase chain reaction. RESULTS: Micro-CT data from the XP-E (n = 21) and BR-Hed (n = 23) protocols revealed no significant differences between groups regarding shaping parameters (canal volume, surface area, structure model index, and prepared walls) after preparation and after the supplementary step (P > .05). All these parameters significantly increased after each preparation step (P < .05), except for structure model index changes after the XP-endo Finisher (P > .05). Bacteriologic data from the XP-E (n = 21) and BR-Hed (n = 22) groups showed that 14 (66.7%) and 10 (45.5%) S2 samples still had detectable bacteria, respectively. The corresponding figures for supplementary steps with the XP-endo Finisher and Hedström file were 11 (52.4%) and 10 (45.5%), respectively. Bacterial counts in sample 1 significantly decreased in samples 2 and 3 in both groups (P < .01). Intragroup comparison between sample 2 and sample 3 showed a 66% reduction in counts after using the Hedström file and 18% after using the XP-endo Finisher (P > .05 for both groups). The quantitative bacterial reduction was not different between groups (P > .05). CONCLUSIONS: The XP-endo Shaper and BioRaCe systems have similar disinfecting and shaping abilities in C-shaped canals. Supplementary steps with the Hedström file and the XP-endo Finisher were similarly effective in improving shaping, but this was not sufficient to enhance disinfection. About half of the cases, in both groups, still harbored detectable amounts of bacteria.

来源:J Endod,查看原文。版权归原作者所有。