文献速递牙体牙髓病

纳米CT评估3D打印牙根管充填体积:5种方法对比

Volumetric Evaluation of 5 Root Canal Obturation Methods in TrueTooth 3-dimensional-Printed Tooth Replicas Using Nano-computed Tomography.
PubMed 文献 · J Endod · 2020-11-25

本研究用纳米CT评估5种根管充填技术在3D打印上颌中切牙模型中总充填体积和空隙体积,每组10个样本。单因素方差分析显示充填技术和材料对充填体积和空隙均有显著影响,SC2、CW和CL组充填体积与SC1和GC组有显著差异。

要点

  • 充填技术和材料显著影响根管充填体积和空隙。
  • SC2、CW和CL组充填体积与SC1和GC组有显著差异。
  • SC1组空隙体积与GC和CL组有显著差异。

核心结论

  • 充填技术和所用材料显著影响充填材料总体积和潜在空隙。

研究设计与样本

  • 研究使用50个3D打印上颌左侧中切牙复制品,随机分为5组(n=10),每组采用不同充填技术,充填后行纳米CT扫描和体积分析。

主要发现

  • 单因素方差分析显示组别对总充填体积有显著影响,事后检验显示SC2、CW和CL组与SC1和GC组有显著差异。
  • 单因素方差分析显示组别对空隙体积有显著影响,事后检验显示SC1组与GC和CL组有显著差异。

关键数值与推荐

  • 每组样本量为n=10,显著性水平设为5%(P < .05)。

临床怎么用

  • 临床选择根管充填技术和材料时需考虑其对充填体积和空隙的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to evaluate the volumes of total obturation and voids in different obturation techniques using nano-computed tomographic imaging. The null hypothesis was that the obturation technique and the materials used have no effect on the total volume of obturation or the total volume of voids. METHODS: Fifty maxillary left central incisor 3-dimensional-printed replicas (TrueTooth; Dental Engineering Laboratories, Santa Barbara, CA) were instrumented and randomly assigned to 5 different obturation groups (n = 10): single cone with EndoSequence Gutta-Percha Points (Brasseler USA, Savannah, GA) and Ribbon Sealer (Dentsply Sirona, Tulsa, OK) (SC1), single cone with BC 150 Series Gutta-Percha Points (Brasseler USA) and EndoSequence BC Sealer (Brasseler USA) (SC2), continuous wave with EndoSequence Gutta-Percha Points and Ribbon Sealer (CW), GuttaCore carrier obturation (Dentsply Sirona) and Ribbon Sealer (GC), and cold lateral condensation with EndoSequence Gutta-Percha Points and Ribbon Sealer (CL). After obturation, nano-computed tomographic images were obtained, and volumetric analysis was performed. Statistical analysis using 1-way analysis of variance (ANOVA). The level of significance was set at 5% (P < .05). RESULTS: The 1-way ANOVA for total obturation indicated a statistically significant effect of group on obturation. Post hoc tests revealed a significant difference between the SC2, CW, and CL groups compared with the SC1 and GC groups. The 1-way ANOVA for calculated voids indicated a statistically significant effect of group on voids. Post hoc tests revealed significant differences between the SC1 group and the GC and CL groups. CONCLUSIONS: This study concluded that obturation technique and the materials used significantly affect the total volume of obturation material and potential for voids.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Holmes S, Gibson R, Butler J, et al. Volumetric Evaluation of 5 Root Canal Obturation Methods in TrueTooth 3-dimensional-Printed Tooth Replicas Using Nano-computed Tomography. J Endod. 2020. PMID: 33245972. doi:10.1016/j.joen.2020.11.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。