三种镍钛系统预备弯曲根管后牙本质微裂纹的微CT评价
本研究使用微CT扫描24颗人下颌磨牙弯曲根管,随机分为PTN、PTG和WOG三组进行预备,比较术前术后牙本质微裂纹。结果显示总体26%的图像存在牙本质缺陷,但所有微裂纹在术前已存在,三种系统均未产生新微裂纹。
要点
- PTN、PTG和WOG预备弯曲根管后未产生新的牙本质微裂纹。
- 术后观察到的微裂纹均存在于术前对应图像中。
- 微CT显示三组术后微裂纹比例分别为24.6%、26%和27.4%。
核心结论
- 使用PTN、PTG和WOG系统进行根管预备未诱导新的牙本质微裂纹形成。
研究设计与样本
- 实验研究,24颗人下颌磨牙弯曲根管,随机分为3组(n=8),分别使用PTN、PTG和WOG预备,微CT扫描分辨率6.78 μm,分析术前术后横截面图像共35304张。
主要发现
- 总体26%的图像(n=9188)存在牙本质缺陷。
- PTN、PTG和WOG组术后图像中牙本质微裂纹分别占24.6%、26%和27.4%。
- 所有微裂纹在术前对应图像中已存在。
临床怎么用
- 提示临床使用PTN、PTG或WOG预备弯曲根管时,无需过度担心器械诱导新微裂纹。
局限性
- 样本量较小(每组8颗牙),仅评估下颌磨牙弯曲根管,离体研究结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro-computed tomographic analysis. METHODS: Twenty-four human mandibular molars with curved roots were scanned in a micro-computed tomographic device using an isotropic resolution of 6.78 μm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre- and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks. RESULTS: Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems. CONCLUSIONS: Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks.
引用
- Miguéns-Vila R, Martín-Biedma B, De-Deus G, et al. Micro-computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments. J Endod. 2020. PMID: 33096193. doi:10.1016/j.joen.2020.10.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。