下颌双种植体覆盖义齿:CAD-CAM 研磨杆远中延伸与固位锚的随机对照试验
1年随访时,两组种植体存活率均为100%,种植体周边缘骨水平变化无显著差异(p=.754),除主观评估(SA)在MBDE组显著更优(p=.022)外,咀嚼效率、最大咬合力、OHIP-EDENT和义齿满意度指数均无组间差异。结论认为短期内(1年)MBDE不低于传统RA覆盖义齿。
要点
- 1年时两组种植体存活率均为100%,无种植体丢失。
- 种植体周边缘骨水平变化组间无显著差异(p=.754)。
- MBDE组主观评估(SA)显著优于RA组(p=.022)。
核心结论
- 短期(1年)内,CAD-CAM研磨杆远中延伸支持的下颌双种植体覆盖义齿不劣于传统固位锚覆盖义齿。
主要发现
- 1年随访时两组均无种植体丢失(ISR=100%)。
- 种植体周边缘骨水平变化组间无显著差异(p=.754)。
- 除主观评估(SA)在MBDE组显著更优(p=.022)外,咀嚼效率(VoH)、最大咬合力(MBF)、OHIP-EDENT和义齿满意度指数(DSI)组间均无差异。
- 实验组改善发生更快,但观察期内除SA外未转化为组间差异。
临床怎么用
- 对于下颌无牙颌患者,CAD-CAM研磨杆远中延伸可作为固位锚覆盖义齿的短期替代方案。
- 短期临床决策可考虑MBDE以可能获得更好的主观评价,但需更多长期证据。
局限性
- 样本量较小(完成1年随访各19例),随访时间仅1年,结论限于短期。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This randomized controlled trial (RCT) aimed to demonstrate the non-inferiority of mandibular 2-implant overdentures (IODs) on a CAD-CAM milled bar with long distal extensions (MBDE) against IODs on retentive anchors (RA). METHODS: Forty edentulous participants rehabilitated with a maxillary conventional denture and a mandibular 2-IOD participated in this trial. They were randomized into two groups [Control group (CG): RA + gold matrices; Experimental group (EG): MBDE + gold clip]. The outcomes included implant survival rate (ISR), chewing efficiency [quantitative (VoH) and subjective (SA) assessments], peri-implant marginal bone levels (PI-MBL), maximum bite force (MBF), and patient-reported outcomes [oral health impact profile (OHIP-EDENT), and denture satisfaction index (DSI)]. Outcomes were recorded at baseline (BL), two weeks (T0 ), 6 months (T1 ), and at 1 year (T2 ) after the intervention. Intra- and inter-group analyses were performed using regression models with ⍺=0.05. RESULTS: 38 participants completed the T2 visit (CG: n = 19, age = 74.7 ± 7.8 years; EG: n = 19, age = 70.3 ± 10.7 years). At T2 , there was no implant loss in either of the groups (ISR = 100%). There were no significant differences between the groups for the PI-MBL changes (p = .754). Improvements occurred faster in the EG than in the CG, but over the observation time, there were no differences between the trial groups for VoH, MBF, OHIP-EDENT, and the DSI, except for SA being significantly better in the EG group (p = .022). CONCLUSIONS: The results of this RCT confirm that mandibular 2-IODs with a CAD-CAM milled bar with long distal extensions are not an inferior treatment to the conventional IODs on retentive anchors in the short term (1 year).
引用
- Srinivasan M, Schimmel M, Buser R, et al. Mandibular two-implant overdentures with CAD-CAM milled bars with distal extensions or retentive anchors: A randomized controlled trial. Clin Oral Implants Res. 2020. PMID: 32965052. doi:10.1111/clr.13668
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。