文献速递口腔修复与种植

小鼠模型揭示种植体超负荷下牙槽骨的力学适应性反应

Mechano-adaptive Responses of Alveolar Bone to Implant Hyper-loading in a pre-clinical in vivo model.
PubMed 文献 · Clin Oral Implants Res · 2020-09-15

结果显示超负荷种植体咬合力增加3.6倍,种植体周围应变升高,骨形成与骨吸收均显著增加,最终种植体周围骨体积分数(BV/TV)显著增加。

要点

  • 小鼠模型中种植体超负荷使咬合力增加3.6倍并升高种植体周围应变
  • 超负荷下种植体周围骨形成与骨吸收均显著增加
  • 超负荷最终导致种植体周围BV/TV显著增加,呈净骨沉积

核心结论

  • 种植体超负荷引起骨应变并同时触发骨吸收与骨形成反应,最终表现为净骨沉积。

主要发现

  • 与对照组相比,超负荷种植体咬合力增加3.6倍,产生更高的种植体周围应变。
  • 超负荷种植体周围骨形成与骨吸收均显著升高。
  • 超负荷组种植体周围骨体积分数(BV/TV)显著增加。

关键数值与推荐

  • 超负荷组咬合力较对照组增加3.6倍。
  • 超负荷组种植体周围BV/TV较对照组显著增加。

临床怎么用

  • 该小鼠模型提示种植体超负荷可同时激活骨改建的分解与合成反应并导致净骨沉积,临床解读种植体周围骨改建时需考虑力学负荷的双向效应。

局限性

  • 证据来自小鼠临床前模型,结论外推至人口腔种植临床情境需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Oral implants transmit biting forces to peri-implant bone. In turn, those forces subject peri-implant bone to mechanical stresses and strains. Here, our objective was to understand how peri-implant bone responded to conditions of normal versus hyper-loading in a mouse model. MATERIAL AND METHODS: Sixty-six mice were randomly assigned to 2 groups; both groups underwent bilateral maxillary first molar extraction followed by complete healing. Titanium alloy implants were placed in healed sites and positioned below the occlusal plane. After osseointegration, a composite crown was affixed to the implant so masticatory loading would ensue. In controls, the remaining dentition was left intact but in the hyper-loaded (test) group, the remaining molars were extracted. 3D finite element analysis (FEA) calculated peri-implant strains resulting from normal and hyper-loading. Peri-implant tissues were analyzed at multiple time points using micro-computed tomography (µCT) imaging, histology, enzymatic assays of bone remodeling, and vital dye labeling to evaluate bone accrual. RESULTS: Compared to controls, hyper-loaded implants experienced a 3.6-fold increase in occlusal force, producing higher peri-implant strains. Bone formation and resorption were both significantly elevated around hyper-loaded implants, eventually culminating in a significant increase in peri-implant bone volume/total volume (BV/TV). In our mouse model, masticatory hyper-loading of an osseointegrated implant was associated with increased peri-implant strain, increased peri-implant bone remodeling, and a net gain in bone deposition. CONCLUSION: Hyper-loading results in bone strain with catabolic and anabolic bone responses, leading to a net gain in bone deposition.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Tian Y, Li Z, Chen J, et al. Mechano-adaptive Responses of Alveolar Bone to Implant Hyper-loading in a pre-clinical in vivo model. Clin Oral Implants Res. 2020. PMID: 32882082. doi:10.1111/clr.13662

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。