文献速递牙周病口腔修复与种植

非增强牙科MRI与CBCT评估上颌磨牙根分叉病变的对比研究

Comparison of non-contrast-enhanced dental magnetic resonance imaging and cone-beam computed tomography in assessing the horizontal and vertical components of furcation defects in maxillary molars: An in vivo feasibility study.
PubMed 文献 · J Clin Periodontol · 2020-10-20

NCE-dMRI与CBCT在缺损分类上具有高可靠性(κ≥0.9)和高一致性,水平与垂直检出的敏感度/特异度分别为98%/100%和99%/99%。

要点

  • NCE-dMRI评估上颌磨牙根分叉缺损与CBCT高度一致,可靠性高。
  • NCE-dMRI对根分叉缺损的检出敏感度和特异度均达98%以上。
  • 缺损分类的敏感度在水平III度和垂直C亚类相对较低。

核心结论

  • 非增强牙科磁共振成像在评估上颌磨牙根分叉缺损时表现出高可靠性和与CBCT的高一致性。

主要发现

  • 共94个根分叉入口观察到根间骨丧失。
  • NCE-dMRI和CBCT的观察者内与观察者间加权κ值均≥0.9。
  • Bland-Altman分析显示水平测量平均差0.12 mm(95%一致性界限-0.67至0.90 mm),垂直测量平均差0.12 mm(95%一致性界限-1.27至1.50 mm)。
  • 以CBCT为参考,NCE-dMRI检测根分叉缺损的敏感度/特异度:水平成分98%/100%,垂直成分99%/99%。
  • 缺损分类敏感度:水平I/II/III度分别为88%/89%/100%,垂直A/B/C亚类分别为95%/91%/80%。

临床怎么用

  • NCE-dMRI可作为无辐射评估上颌磨牙根分叉缺损的可行影像学方法,与CBCT结果高度一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare non-contrast-enhanced dental magnetic resonance imaging (NCE-dMRI) and cone-beam computed tomography (CBCT) in assessing horizontal and vertical furcation defects in maxillary molars in vivo. MATERIALS AND METHODS: (NCE-dMRI) and CBCT were performed in 23 patients with severe periodontitis. Sixty-five first/second maxillary molars (195 furcation entrances) were analysed by two independent observers on both modalities to assess the horizontal and vertical components of furcation defects. Reliability of defect classification was evaluated using weighted kappa (κ) statistics. Agreement between NCE-dMRI and CBCT was determined by the Bland-Altman analysis. Sensitivity and specificity of NCE-dMRI were calculated using CBCT as the reference. RESULTS: Inter-radicular bone loss was observed in 94 furcation entrances. Intra- and inter-rater κ-values were ≥0.9 for both NCE-dMRI and CBCT. The Bland-Altman analysis showed mean differences (95% limits of agreement) of 0.12 mm (-0.67 to 0.90) for horizontal and 0.12 mm (-1.27 to 1.50) for vertical measurements. For the detection of furcation defects, sensitivity/specificity of NCE-dMRI was 98%/100% for horizontal and 99%/99% for vertical components. For defect classification, sensitivity values of NCE-dMRI were 88%/89%/100% (horizontal degree I/II/III) and 95%/91%/80% (vertical subclass A/B/C), respectively. CONCLUSIONS: Non-contrast-enhanced dental magnetic resonance imaging demonstrated high reliability and high agreement with CBCT for the assessment of furcation defects in maxillary molars.

来源:J Clin Periodontol,查看原文。版权归原作者所有。

引用

  1. Juerchott A, Sohani M, Schwindling FS, et al. Comparison of non-contrast-enhanced dental magnetic resonance imaging and cone-beam computed tomography in assessing the horizontal and vertical components of furcation defects in maxillary molars: An in vivo feasibility study. J Clin Periodontol. 2020. PMID: 32990988. doi:10.1111/jcpe.13374

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。