文献速递牙体牙髓病

不同流速下注射器冲洗对模拟峡部与侧支根管生物膜的清除效果:实验与CFD结合研究

Biofilm removal from a simulated isthmus and lateral canal during syringe irrigation at various flow rates: a combined experimental and Computational Fluid Dynamics approach.
PubMed 文献 · Int Endod J · 2020-11-18

结果显示流速对生物膜清除的影响大于次氯酸钠浓度,模型预测的冲洗液速度与生物膜清除模式相符。

要点

  • 冲洗液流速对模拟峡部和侧支根管生物膜清除的影响大于次氯酸钠浓度。
  • 第一阶段流速和第二阶段额外高速冲洗均显著影响峡部残留生物膜。
  • 侧支根管中第二阶段额外冲洗的显著效果仅在中或高流速冲洗之后出现。

核心结论

  • 冲洗液流速对体外模拟峡部和侧支根管的生物膜清除影响大于次氯酸钠浓度。
  • 计算流体动力学模型预测的冲洗液速度与模拟峡部和侧支根管的生物膜清除模式相符。

研究设计与样本

  • 第一阶段用2%、5%、10%次氯酸钠或黏附缓冲液以0.033、0.083、0.166 mL/s流速或被动沉积冲洗30秒,随后所有样本用黏附缓冲液以0.166 mL/s冲洗30秒。
  • 用光学相干断层扫描测定残留生物膜百分比,采用两次三因素混合设计方差分析(α=0.05),并用计算流体动力学模型模拟冲洗液流动。

主要发现

  • 第一阶段流速和第二阶段额外冲洗对峡部残留生物膜百分比有显著影响(P=0.004和P<0.001)。
  • 第二阶段额外冲洗对侧支根管残留生物膜也有显著影响(P≤0.007),但仅当第一阶段为中或高流速冲洗时。
  • 次氯酸钠浓度的影响不显著(P>0.05)。
  • 峡部和侧支根管中冲洗液速度随流速增加而增加,且与这些区域的生物膜清除 substantially 相关。

临床怎么用

  • 临床冲洗时应优先考虑提高冲洗液流速以增强峡部和侧支根管的生物膜清除。
  • 在次氯酸钠冲洗后增加一次高速终末冲洗可能有助于改善峡部和侧支根管的清洁效果。

局限性

  • 研究为体外人工根管系统模型,结果不能直接等同于临床真实根管解剖和生物膜条件。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: (i) To quantify biofilm removal from a simulated isthmus and a lateral canal in an artificial root canal system during syringe irrigation with NaOCl at different concentrations and delivered at various flow rates (ii) to examine whether biofilm removal is further improved by a final high-flow-rate rinse with an inert irrigant following irrigation with NaOCl. (iii) to simulate the irrigant flow in these areas using a computer model (iv) to examine whether the irrigant velocity calculated by the computer model is correlated to biofilm removal. METHODOLOGY: Ninety-six artificial root canals with either a simulated isthmus or lateral canal were used. A dual-species in vitro biofilm was formed in these areas using a Constant Depth Film Fermenter. NaOCl at various concentrations (2, 5 and 10%) or adhesion buffer (control) was delivered for 30 s by a syringe and an open-ended needle at 0.033, 0.083, or 0.166 mL s-1 or passively deposited in the main root canal (phase 1). All specimens were subsequently rinsed for 30 s with adhesion buffer at 0.166 mL s-1 (phase 2). The biofilm was scanned by Optical Coherence Tomography to determine the percentage of the remaining biofilm. Results were analysed by two 3-way mixed-design ANOVAs (α = 0.05). A Computational Fluid Dynamics model was used to simulate the irrigant flow inside the artificial root canal system. RESULTS: The flow rate during phase 1 and additional irrigation during phase 2 had a significant effect on the percentage of the remaining biofilm in the isthmus (P = 0.004 and P < 0.001). Additional irrigation during phase 2 also affected the remaining biofilm in the lateral canal significantly (P ≤ 0.007) but only when preceded by irrigation at medium or high flow rate during phase 1. The effect of NaOCl concentration was not significant (P > 0.05). Irrigant velocity in the isthmus and lateral canal increased with increasing flow rate and it was substantially correlated to biofilm removal from those areas. CONCLUSIONS: The irrigant flow rate affected biofilm removal in vitro more than NaOCl concentration. Irrigant velocity predicted by the computer model corresponded with the pattern of biofilm removal from the simulated isthmus and lateral canal.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Pereira TC, Boutsioukis C, Dijkstra RJB, et al. Biofilm removal from a simulated isthmus and lateral canal during syringe irrigation at various flow rates: a combined experimental and Computational Fluid Dynamics approach. Int Endod J. 2020. PMID: 32990985. doi:10.1111/iej.13420

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。