文献速递口腔修复与种植牙周病

分形分析无法区分种植体周围黏膜健康与疾病状态

Validity of fractal analysis of implants in individuals with healthy and diseased peri-implant mucosa.
PubMed 文献 · Clin Oral Implants Res · 2020-09-02

结果显示仅FD在各组间无显著差异(p=.559),而探诊深度、临床附着水平和探诊出血均有显著差异(p<.001)。结论认为FD不是区分健康与疾病种植体的有效方法。

要点

  • 分形维数在健康、黏膜炎和种植体周围炎三组间无显著差异(p=.559)。
  • 探诊深度、临床附着水平和探诊出血在三组间均有显著差异(p<.001)。
  • 根尖片分形分析不能作为鉴别种植体周围健康与疾病的诊断工具。

核心结论

  • 基于根尖片计算的种植体周围骨分形维数不能有效区分健康与疾病种植体。
  • 临床指标探诊深度、临床附着水平和探诊出血对诊断种植体周围健康、黏膜炎和种植体周围炎有用。

研究设计与样本

  • 从电子健康记录提取种植体的探诊深度、临床附着水平和探诊出血,并使用数字根尖片在两个感兴趣区计算分形维数。
  • 采用单因素方差分析比较组间差异,Spearman非参数相关分析评估指标间相关性。

主要发现

  • 分形维数是唯一在各组间无显著差异的指标(p=.559)。
  • 探诊深度、临床附着水平和探诊出血百分比在各组间均有显著差异(p<.001)。

关键数值与推荐

  • 分形维数组间比较p=.559。
  • 探诊深度、临床附着水平和探诊出血百分比组间比较p<.001。

临床怎么用

  • 临床诊断种植体周围健康、黏膜炎和种植体周围炎应依据探诊深度、临床附着水平和探诊出血。
  • 不应依赖根尖片分形分析来鉴别种植体周围骨的健康与疾病状态。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The purpose of this study was to determine whether fractal analysis could discriminate the peri-implant trabecular bone between individuals with healthy peri-implant mucosa and peri-implant disease using digital periapical radiographs. MATERIAL AND METHODS: The electronic health records of patients with a dental implant were reviewed to determine their eligibility. One hundred four patients (aged 27-89 years) were included and divided into three groups. Group 1) Individuals with healthy peri-implant mucosa; Group 2) Individuals with peri-implant mucositis; or Group 3) Individuals with peri-implantitis. The following clinical measurements for each dental implant were extracted: probing depth (PD), clinical attachment level (CAL), and the presence or absence of bleeding on probing (BOP). Digital periapical images of the implant were used to calculate the fractal dimension (FD) for each implant at two regions of interest (ROI). Summary statistics were calculated for mean PD, mean CAL, mean percent BOP, and mean FD by group. Differences among groups were tested using one-way analysis of variance (ANOVA). Spearman nonparametric correlations were tabulated for mean PD, mean CAL, mean percent BOP, and mean FD. RESULTS: The only measure that did not demonstrate significant differences among groups was FD (p = .559) with all other measures demonstrating a significant difference (p < .001). CONCLUSIONS: Based on this study, FD of the peri-implant bone calculated from a periapical radiograph does not appear to be a valid method to distinguish between healthy and diseased implants, while clinical measures of PD, CAL, and BOP are useful for the diagnosis of peri-implant health, peri-implant mucositis, and peri-implantitis.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Lang MS, Miyamoto T, Nunn ME, et al. Validity of fractal analysis of implants in individuals with healthy and diseased peri-implant mucosa. Clin Oral Implants Res. 2020. PMID: 32790884. doi:10.1111/clr.13650

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。