唾液MMP-9侧流试验即时检测对牙周炎的诊断能力
这项横断面研究纳入137名参与者,评估唾液基质金属蛋白酶-9侧流试验即时检测试剂盒对牙周炎的诊断能力,并开发诊断算法。结果显示该检测的曲线下面积为0.82(敏感度0.92,特异度0.72),结合年龄、性别、吸烟和肥胖的算法曲线下面积达0.88(敏感度0.92,特异度0.85),提示该试剂盒可作为牙周炎筛查的有效工具。
要点
- 唾液MMP-9侧流试验即时检测对牙周炎诊断的曲线下面积为0.82。
- 结合年龄、性别、吸烟和肥胖的算法曲线下面积提升至0.88。
- 该试剂盒有望成为牙周炎筛查的高效工具。
核心结论
- 唾液MMP-9侧流试验即时检测试剂盒对牙周炎显示出适当的诊断能力,可作为牙周炎筛查的有效工具。
研究设计与样本
- 横断面研究,通过首尔国立牙科医院招募137名参与者(46例侧流试验阴性,91例阳性)。
- 使用150μl非刺激唾液进行侧流试验即时检测,以改良新国际分类系统的II-IV期作为牙周炎诊断标准。
主要发现
- 唾液MMP-9侧流试验即时检测在全部参与者中的诊断能力为0.82(敏感度0.92,特异度0.72)。
- 诊断算法(算法评分=-3.675+2.877*侧流试验+0.034*年龄+0.121*性别+0.372*吸烟+0.192*肥胖)的诊断能力为0.88(敏感度0.92,特异度0.85),截断值为0.589。
关键数值与推荐
- 牙周炎诊断采用改良新国际分类系统的II-IV期标准。
- 侧流试验即时检测诊断能力曲线下面积0.82,敏感度0.92,特异度0.72。
- 诊断算法曲线下面积0.88,敏感度0.92,特异度0.85,截断值0.589。
临床怎么用
- 唾液MMP-9侧流试验即时检测可用于牙周炎的初步筛查。
- 结合年龄、性别、吸烟和肥胖的算法可提高诊断特异度至0.85。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: This cross-sectional study aimed to examine the diagnostic ability of salivary matrix metalloproteinase (MMP)-9 lateral flow test (LFT) point-of-care (POC) kit and develop an algorithm for diagnosis of periodontitis. MATERIALS AND METHODS: Through Seoul National Dental Hospital, 137 participants (46 LFT negatives, 91 LFT positives) were recruited. For salivary diagnostics, 150 μl of the unstimulated saliva was applied to LFT-POC kit. To make a diagnosis of periodontitis, stage II-IV in modified new international classification system was used. Covariates encompassing age, sex, smoking and obesity were evaluated through face-to-face interview. Enzyme-linked immunosorbent assay was used for quantification of salivary MMP-9. To develop a diagnostic algorithm, multivariable logistic regression analysis was used. Receiver operating characteristic curve was applied for evaluating diagnostic ability. RESULTS: Diagnostic ability of salivary MMP-9 LFT-POC test was 0.82 (sensitivity of 0.92, specificity of 0.72) in total participants. Diagnostic algorithm using POC test resulted in a response equation, that is algorithm score = -3.675 + 2.877*LFT + 0.034*age + 0.121*sex + 0.372*smoking + 0.192*obesity. Diagnostic ability of the algorithm was 0.88 (sensitivity of 0.92, specificity of 0.85) with cut-off score of 0.589. CONCLUSIONS: Salivary MMP-9 LFT-POC kit showed appropriate diagnostic ability for periodontitis and would be an efficient tool for screening of periodontitis.
引用
- Kim HD, Lee CS, Cho HJ, et al. Diagnostic ability of salivary matrix metalloproteinase-9 lateral flow test point-of-care test for periodontitis. J Clin Periodontol. 2020. PMID: 32841379. doi:10.1111/jcpe.13360
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。