不同开髓洞修复材料对烤瓷熔附金属冠固位力的体外比较
结果显示开髓后固位力显著下降,各修复方案均使固位力超过原始值且组间无统计学差异。
要点
- 开髓会显著降低烤瓷熔附金属冠的固位力。
- 银汞、复合树脂、银汞加复合树脂或桩加复合树脂修复均可恢复并超过原始固位力。
- 不同修复材料方案之间的固位力无统计学差异。
核心结论
- 开髓洞会降低烤瓷熔附金属冠的固位力,但后续用银汞合金、复合树脂、银汞加复合树脂或桩加复合树脂修复可提高至超过原始固位力。
研究设计与样本
- 开髓后重新粘冠,分别用银汞合金或复合树脂修复开髓洞后再次测量脱位力。
- 去除修复材料后测量开髓面积,再分别用银汞加复合树脂或纤维桩加复合树脂修复并再次测量脱位力。
- 采用配对t检验比较组间脱位力均值,单因素方差分析比较组内均值。
主要发现
- 未充填开髓后的固位力显著低于完整冠。
- 银汞合金、复合树脂、银汞加复合树脂、纤维桩加复合树脂均使固位力超过原始值。
- 不同修复方案之间无统计学差异。
- 定性结果显示无论使用何种修复材料,脱位后修复材料仍留在冠内。
临床怎么用
- 对需开髓的烤瓷熔附金属冠患者,开髓后应使用银汞合金、复合树脂、银汞加复合树脂或纤维桩加复合树脂修复开髓洞以恢复固位力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate the effect of different access opening restorative materials on crown retention. METHODS: Thirty-eight extracted molars were mounted in resin and prepared for porcelain fused to metal (PFM) crowns. The crowns were fabricated and cemented with zinc phosphate, and the force to displace it was measured with a tensile-testing machine before and after endodontic access preparations. The endodontic access area, crown preparation axial wall, and preparation surface area were measured for comparison. The crowns were then recemented, and access openings were restored with either amalgam or composite before displacement force was remeasured. The restorative material was removed from each access opening; access area was measured and restored again (amalgam with composite or fiber post with composite) for displacement force to be remeasured. Paired t test was used to compare the means of displacement between groups. One-way analysis of variance was used to compare the mean outcome measure within the groups. RESULTS: Statistical analyses showed retention after unfilled access was significantly lower than intact crowns. Amalgam, composite, amalgam + composite, and fiber post + composite increased retention beyond the original value. There was no statistical difference among the different restorative protocols. Qualitative results indicate that the restorative material remains in the crown after displacement regardless of the material used to restore the access. CONCLUSIONS: The results from this study suggest that an endodontic access cavity decreases retention of a PFM crown. However, subsequent restoration with amalgam, composite, amalgam + composite, or post + composite may increase the original retention of the crown.
引用
- Brezinsky S, Bowles W, McClanahan S, et al. In Vitro Comparison of Porcelain Fused to Metal Crown Retention after Endodontic Access and Subsequent Restoration: Composite, Amalgam, Amalgam with Composite Veneer, and Fiber Post with Composite. J Endod. 2020. PMID: 32818565. doi:10.1016/j.joen.2020.08.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。