小电解液池电化学溶解根管内镍钛器械断片的体外研究
该体外研究评估了在离体上颌磨牙根管中,使用双电极和小电解液池电化学溶解镍钛器械断片的可行性。结果显示,所有样本在溶解后均可用08号K锉旁路通过,断片体积显著减小,但长度和孔隙率无显著变化。
要点
- 双电极小电解液池法可显著减小根管内镍钛断片体积
- 溶解后所有样本均可用08号K锉旁路通过断片
- 断片长度和孔隙率在溶解前后无显著变化
核心结论
- 双电极小电解液池电化学溶解法可显著减小离体上颌磨牙根管内镍钛断片体积,并实现08号K锉旁路通过。
研究设计与样本
- 体外研究,使用F1 ProTaper断片在模拟根管和离体上颌磨牙远中颊根管中进行电化学溶解。
- 采用双电极,电解液限制在与树脂块或髓腔耦合的丙烯酸微池中。
- 溶解前后进行Micro-CT分析断片体积、长度和孔隙率,使用配对t检验(P<0.05)比较。
主要发现
- 溶解后所有样本(模拟根管和离体牙)均可用08号K锉被动旁路通过断片。
- 断片体积显著减小(配对t检验,P<0.05)。
- 断片长度和孔隙率无显著减小。
临床怎么用
- 该技术可能为根管内镍钛断片的旁路通过提供新方法,但需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the viability of the electrochemical dissolution of fragments of fractured NiTi instruments in root canals of extracted human maxillary molars, using two electrodes and the solution restricted to a small reservoir coupled to the pulp chamber. The primary hypothesis was that this method enables the reduction of fragment volume and re-establishment of the root canal path with a size 08 K-file, both in simulated canals and in extracted human maxillary molars. METHODOLOGY: Fragments of F1 ProTaper instruments were polarized in simulated root canals and in distobuccal root canals of extracted maxillary molars using a new method, with the solution restricted to a small acrylic microcell coupled to each resin block or pulp chamber. Two electrodes were used, where one was kept in contact with the intracanal fragment and another was positioned in the solution present in the acrylic microcell. After the tests, a size 08 K-file was used passively to verify the possibility of bypassing the fragment, which was also confirmed by radiographic analysis. Micro-CT analysis of the teeth was used before and after fragment dissolution to evaluate the volume, length and porosity of the fragments. The D'Agostino-Pearson normality test was used to verify the distribution of the data. A paired t-test (P < 0.05) was used to compare the volume, length and porosity of the fragments before and after the dissolution tests. RESULTS: After dissolution, all fragments could be bypassed with a size 08 K-file in both simulated canals and in extracted teeth. The dissolution process did not result in significant reduction of neither the fragment length nor the fragment porosity. However, it resulted in a significant reduction of fragment volume (paired t-test, P < 0.05). CONCLUSION: The electrochemical dissolution of fragments of NiTi files in root canals of extracted human maxillary molars using two electrodes, and the solution restricted to a small reservoir coupled to the pulp chamber resulted in a significant reduction of fragment volume. The re-establishment of the root canal path with the passive insertion of size 08 K-files was possible in all samples after the tests, both in simulated canals and in extracted teeth.
引用
- Amaral CCF, Ormiga F, Araújo OMO, et al. Electrochemical dissolution of nickel-titanium instrument fragments in root canals of extracted human maxillary molars using a small reservoir of electrolyte. Int Endod J. 2020. PMID: 32767773. doi:10.1111/iej.13381
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。