文献速递牙体牙髓病

糖尿病对牙本质小管密度及MTA推出粘接强度的影响

Effect of Diabetes on Tubular Density and Push-out Bond Strength of Mineral Trioxide Aggregate to Dentin.
PubMed 文献 · J Endod · 2020-07-29

本研究比较糖尿病与非糖尿病患者的牙本质小管密度及MTA推出粘接强度。糖尿病组MTA推出粘接强度显著降低,小管密度显著增高,失败模式不同(P < .05)。

要点

  • 糖尿病患者的牙本质小管密度显著高于非糖尿病患者。
  • 糖尿病患者的MTA与牙本质推出粘接强度显著降低。
  • 糖尿病患者的MTA-牙本质界面失败模式不同,或可解释根管治疗失败率较高。

核心结论

  • 糖尿病患者的牙本质表现出不同的理化性质。
  • 糖尿病患者的失败模式可由推出粘接强度改变、牙本质-牙髓复合体钙化机制变化、牙本质小管密度增高及小管周牙本质减少解释。
  • 这些差异或可解释糖尿病患者根管治疗失败率较高。

研究设计与样本

  • 比较糖尿病与非糖尿病患者的离体单根牙,每组5颗(n = 5)。
  • 牙根截冠后预备至#5 Gates-Glidden钻,于根中区域水平切取3个2 mm厚牙本质切片(1个用于推出测试,2个用于小管密度测试)。
  • MTA充填根管后孵育3天,用万能试验机测定推出粘接强度。
  • 在体视显微镜和扫描电镜下观察粘接-牙本质界面失败类型。

主要发现

  • 糖尿病患者的MTA与根管牙本质推出粘接强度显著降低(P < .05)。
  • 两组MTA-牙本质界面失败模式不同。
  • 糖尿病患者牙本质小管密度显著增高(P < .05)。

临床怎么用

  • 对糖尿病患者行根管治疗时,应考虑牙本质理化性质改变对粘接和失败模式的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study compared the tubular density and push-out bond strength of mineral trioxide aggregate (MTA) to dentin in diabetic and nondiabetic patients. METHODS: Ten extracted single-rooted human teeth from diabetic and nondiabetic patients (n = 5 in each group) were decoronated, prepared up to a #5 Gates-Glidden drill, and sectioned horizontally at the midroot area to prepare 3 dentin slices, each measuring 2 mm in thickness (1 slice for the push-out test and 2 slices for the tubular density test). MTA was prepared and packed into the root canal space followed by incubation for 3 days. The push-out bond strength values were determined using a universal testing machine. Specimens were viewed under a stereomicroscope and a scanning electron microscope to determine the failure types at the cement-dentin interface. Ten slice specimens in each group were evaluated under SEM at 3 different sites to determine the tubular density. Comparisons were performed using the Mann-Whitney U test (P < .05). RESULTS: Diabetic patients exhibited significantly lower push-out bond strength of MTA to root canal dentin (P < .05). The pattern of failure at the MTA-dentin interface was different between the 2 groups. The tubular density was significantly higher in diabetic patients (P < .05). CONCLUSIONS: The dentin in diabetic patients exhibited different physicochemical properties. The failure patterns and modes in diabetic patients might be explained by the changes in the push-out bond strength, the calcification mechanism of the dentin-pulp complex, a higher dentinal tubule density, and less peritubular dentin. These differences could explain the higher failure rate of root canal treatment in these patients.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Saghiri MA, Karamifar K, Fakharzadeh A, et al. Effect of Diabetes on Tubular Density and Push-out Bond Strength of Mineral Trioxide Aggregate to Dentin. J Endod. 2020. PMID: 32738338. doi:10.1016/j.joen.2020.07.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。