化学机械预备后持续存在活跃细菌的RNA与DNA分子研究
该研究对40颗初治根尖感染牙在化学机械预备前后取样,用rDNA和rRNA为基础的qPCR检测总细菌及四种特定菌。结果显示CMP大幅降低总细菌、Selenomonas spp.和粪肠球菌水平,但Bacteroidaceae sp. HOT-272和C. acnes水平无显著变化且保持代谢活性。rDNA-qPCR敏感性低但特异性高。
要点
- CMP有效降低总细菌量但未能消除细菌代谢活性。
- Bacteroidaceae sp. HOT-272和C. acnes是持续感染社区中的活跃成员。
- rDNA-qPCR在器械后样本中假阳性风险低但敏感性低于RT-qPCR。
核心结论
- 化学机械预备降低了细菌总量但未降低总细菌的代谢活性,Bacteroidaceae sp. HOT-272和C. acnes是持续存在的活跃细菌。
研究设计与样本
- 研究纳入40颗初治根尖感染牙,在化学机械预备前后取样,提取DNA和cDNA进行qPCR检测。
主要发现
- CMP后总细菌、Selenomonas spp.和粪肠球菌数量大幅减少,而Bacteroidaceae sp. HOT-272和C. acnes水平无显著差异。
- S2样本中总细菌、Bacteroidaceae sp. HOT-272和C. acnes的rRNA拷贝浓度显著高于rDNA(P < .05)。
- 与RT-qPCR相比,rDNA-qPCR敏感性低、特异性高,多数检测中rDNA阳性样本rRNA也阳性(阳性预测值=100%)。
临床怎么用
- 提示CMP后仍需关注持续活跃的Bacteroidaceae sp. HOT-272和C. acnes,可考虑辅助抗菌措施。
- rDNA-qPCR假阳性风险低,但阴性结果不能排除活跃细菌存在,必要时结合RT-qPCR。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Because active cells present higher abundance of ribosomal RNA (rRNA) than rDNA (rRNA genes), data obtained with rDNA-based quantitative polymerase chain reaction (qPCR) and rRNA-based qPCR (RT-qPCR) were correlated to search for active bacteria after chemomechanical procedures (CMP). In addition, the ability of both assays to detect bacteria in endodontic samples was evaluated. METHODS: Samples were taken from 40 teeth with primary endodontic infections before (S1) and after CMP (S2). DNA and cDNA (synthetized from RNA) were used as templates for qPCR using universal primers for bacteria and species-specific primers for Bacteroidaceae sp. HOT-272, Cutibacterium acnes, Selenomonas spp., and Enterococcus faecalis. RESULTS: After CMP, there was a drastic reduction in the number of total bacteria, Selenomonas spp., and E. faecalis, whereas no significant difference was observed for the levels of Bacteroidaceae sp. HOT-272 and C. acnes. The concentration of rRNA copies in S2 samples was significantly higher than the corresponding levels of rDNA for assays targeting total bacteria, Bacteroidaceae sp. HOT-272, and C. acnes (P < .05), indicating persistence of active bacteria. The rDNA-based qPCR presented low sensitivity and high specificity when compared with RT-qPCR. For most assays, samples positive for rDNA were also positive for rRNA (positive predictive value = 100%). CONCLUSIONS: CMP was effective in reducing levels but not the metabolic activity of total bacteria. Bacteroidaceae sp. HOT-272 and C. acnes were active members of the persistent community. Although less sensitive than RT-qPCR, most rDNA-based qPCR assays had a low risk of providing false-positive results in postinstrumentation samples.
引用
- Nardello LCL, Vilela BG, Fernandes FS, et al. Analysis of Active Bacteria Persisting after Chemomechanical Procedures: An RNA- and DNA-based Molecular Study. J Endod. 2020. PMID: 32805336. doi:10.1016/j.joen.2020.08.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。