锥形束CT检测根管内分离器械的准确性研究
结果显示数字根尖片准确性83.3%、敏感性37.5%,为最优方法;CBCT各协议均未识别出分离器械,多数分离器械未被检出。
要点
- 数字根尖片识别充填根管内分离器械的敏感性仅37.5%,多数器械漏诊。
- 三种CBCT协议(ICC、ICN、PXD)均未识别出分离器械。
- 器械类型(不锈钢手用锉或往复器械)不影响识别结果。
核心结论
- 数字根尖片在评估根管内分离器械方面优于ICC、ICN和PXD三种CBCT成像协议,但多数分离器械仍未被识别。
研究设计与样本
- 比较i-CAT Classic(0.25 mm各向同性体素)、i-CAT Next Generation(0.125 mm各向同性体素)、PreXion 3D(0.09 mm各向同性体素)三种CBCT协议与数字根尖片。
- 数字根尖片参数为08 mA、70 kVp、曝光时间0.2秒;由两名校准的牙髓专科医生按5分制评估。
- 数据采用Fisher精确检验和二项检验分析。
主要发现
- 数字根尖片识别出9个器械(37.5%),CBCT各协议均未识别出器械(P > .05)。
- 器械类型(不锈钢手用锉或往复器械)不影响分离器械的识别(P > .05)。
- 数字根尖片准确性为83.3%、敏感性为37.5%,为各方法中最高的准确性和敏感性。
临床怎么用
- 在评估充填根管内是否存在分离器械时,数字根尖片可作为优先选择的影像学检查。
- 不应依赖本研究所用CBCT协议排除根管内分离器械,因阴性结果常见。
局限性
- 多数分离器械未被任何方法识别,检出能力整体有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study compared the accuracy, sensitivity, and specificity of different imaging diagnostic protocols, cone-beam computed tomography (CBCT) and digital periapical radiography (DPR), in identifying separated endodontic instruments in filled root canals. METHODS: One hundred eight root canals from 36 mandibular molars were prepared and obturated. Of these, 84 were filled without separated instruments, and 24 were filled with the presence of a separated instrument (stainless steel hand file or reciprocating instrument). Subsequently, different CBCT imaging protocols were acquired: i-CAT Classic (ICC) (0.25-mm isotropic voxel), i-CAT Next Generation (ICN) (0.125-mm isotropic voxel), and PreXion 3D (PXD) (0.09-mm isotropic voxel). Moreover, a DPR exam was obtained (08 mA, 70 kVp, and exposure time of 0.2 seconds). Two calibrated endodontists evaluated each image for the presence or absence of fractured files on a 5-point scale, ranging from definitely absent to definitely present. The accuracy, sensitivity, and specificity measures for each method were estimated. The data were evaluated by Fisher exact test and binomial test. RESULTS: Nine instruments were identified in DPR (37.5%) and none in the CBCT protocols (P > .05). The type of instrument (stainless steel hand file or reciprocating instrument) did not influence the identification of the separated instrument (P > .05). This study showed that DPR is the most accurate and sensitive imaging technique, with 83.3% and 37.5%, respectively. CONCLUSIONS: DPR is the better imaging diagnostic exam to evaluate the presence of separated endodontic instruments inside a root canal in comparison with the ICC, ICN, and PXD tomographic protocols. However, most of the separated instruments were not identified.
引用
- Baratto-Filho F, Vavassori de Freitas J, Fagundes Tomazinho FS, et al. Cone-Beam Computed Tomography Detection of Separated Endodontic Instruments. J Endod. 2020. PMID: 32818562. doi:10.1016/j.joen.2020.08.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。