热处镍钛旋转系统在弯曲根管预备与根尖扩大中的微CT评价
本研究用微CT比较热处与热/表面处理镍钛旋转系统预备弯曲根管及根尖扩大的效果。48个下颌磨牙弯曲近中根管(20°-40°)分别用PDL或HFEDM预备至25号,再扩大至40号。HFEDM组根管体积增加更大,两组清洁能力相似,扩大至40号均减少碎屑和未接触面并保持根管中心化。
要点
- HFEDM预备后根管体积增加大于PDL。
- 两组碎屑百分比和未接触面百分比相似。
- 根尖扩大至40号可减少碎屑和未接触面。
核心结论
- HFEDM器械比PDL产生更大的根管体积增加,但两者清洁能力相似。
- 两种器械根尖扩大至40号均减少碎屑和未接触面,并使弯曲根管保持中心化。
研究设计与样本
- 体外研究,使用48个下颌磨牙弯曲近中根管(20°-40°),用微CT(9 μm)扫描分析。
主要发现
- HFEDM在预备后和根尖扩大后根管体积增加均高于PDL(P < .05)。
- 根尖扩大使两组碎屑和未接触面显著减少(P < .05)。
- 预备后和根尖扩大后,两组碎屑百分比和未接触面百分比相似(P > .05)。
- 两种系统均使根管中心化(P > .05)。
临床怎么用
- 弯曲根管预备可选用HFEDM以获得更大体积增加,根尖扩大至40号有助于减少碎屑和未接触面。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to evaluate root canal preparation and apical enlargement of curved canals using rotary heat-treated and heat/surface-treated systems by micro-computed tomographic imaging. METHODS: Curved mesial root canals (n = 48) of mandibular molars (20°-40°) were prepared using ProDesign Logic (PDL; Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil) 25/.01 and 25/.06 or HyFlex EDM (HFEDM) 10/.05, HyFlex CM 20/.04, and HFEDM 25/.08. Apical enlargement was performed using PDL 40/.05 or HFEDM 40/.04. Scanning (9 μm) was performed before and after preparation and after apical enlargement using micro-computed tomographic imaging. Volume, percentage of volume increase, debris, untouched root canal surface, and centering ability were analyzed. Statistical analysis was performed using Mann-Whitney, Wilcoxon, and unpaired t tests (α = .05). RESULTS: HFEDM promoted a higher volume increase of the root canals than PDL after preparation and after apical enlargement (P < .05). The apical enlargement promoted a significant decrease in debris and untouched surface in both groups (P < .05). The percentage of debris and untouched surface were similar between HFEDM and PDL after preparation and after apical enlargement (P > .05). Both systems promoted centered canals (P > .05). CONCLUSIONS: HFEDM instruments promoted greater volume of the root canal than PDL. However, the cleaning ability of the instruments was similar. The apical increase up to size 40 with both instruments provided less debris and untouched surfaces and allowed centralization of the curved root canals.
引用
- Pivoto-João MMB, Tanomaru-Filho M, Pinto JC, et al. Root Canal Preparation and Enlargement Using Thermally Treated Nickel-Titanium Rotary Systems in Curved Canals. J Endod. 2020. PMID: 32818566. doi:10.1016/j.joen.2020.08.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。