光功能化改善动物模型种植体骨结合的系统综述与荟萃分析
该系统综述与荟萃分析检索8个数据库,纳入10项动物研究,评估光功能化对种植体骨结合的影响。结果显示光功能化在兔、犬、大鼠中均提高骨-种植体接触率(BIC)和推出强度,但在12周随访时BIC无显著差异。结论认为光功能化可改善种植体初始愈合期的骨结合。
要点
- 光功能化在兔、犬、大鼠模型中均显著提高骨-种植体接触率(BIC)。
- 光功能化组推出强度显著高于对照组,但异质性高(I2=90%)。
- 12周随访时BIC无显著差异,提示获益主要在初始愈合期。
核心结论
- 光功能化可改善兔、犬、大鼠模型中种植体初始愈合期的骨结合。
研究设计与样本
- 系统综述与荟萃分析,检索8个数据库,最终纳入10项动物研究进行荟萃分析。
- 采用SYRCLE偏倚风险工具评估内部真实性,GRADE方法评估证据确定性。
主要发现
- 异质性:兔I2=24%,犬I2=0%,大鼠I2=0%,汇总BIC I2=49%,推出强度I2=90%。
临床怎么用
- 动物模型证据提示光功能化可能促进种植体早期骨结合,但需谨慎外推至临床。
局限性
- 纳入研究均为动物实验,证据确定性需参考GRADE评估结果。
- 推出强度分析异质性高(I2=90%),结果解释需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To determine whether photofunctionalization influences dental implant osseointegration. MATERIAL AND METHODS: Data on osseointegration rates were extracted from 8 databases, based on bone-to-implant contact (BIC) and pushout tests. Internal validity was accessed through the SYRCLE risk of bias tool for animal experimental studies. Meta-analyses were performed for investigation of the influence of photofunctionalization on implant osseointegration, with a random effect and a confidence interval of 95%. The certainty of evidence was accessed through the GRADE approach. RESULTS: Thirty-four records were identified, and 10 were included in the meta-analysis. Photofunctionalized implants showed higher mean values for BIC in rabbits (MD 6.92 [1.01, 12.82], p = .02), dogs (MD 23.70 [10.23, 37.16], p = .001), rats (MD 20.93 [12.91, 28.95], p < .0001), and in the pooled BIC analyses (MD 14.23 [7.80, 20.66], p < .0001) compared to those in control implants in the overall assay. Conversely, at late healing periods, the pooled BIC meta-analyses showed no statistically significant differences (p > .05) for photofunctionalized and control implants at 12 weeks of follow-up. For pushout analysis, photofunctionalized implants presented greater bone strength integration (MD 19.92 [13.88, 25.96], p < .0001) compared to that of control implants. The heterogeneity between studies ranged from "not important" to "moderate" for rabbits I2 = 24%, dogs I2 = 0%, rats I2 = 0%, and pooled BIC (I2 = 49%), while considerable heterogeneity was observed for pushouts (I2 = 90%). CONCLUSION: Photofunctionalization improves osseointegration in the initial healing period of implants, as summarized from available data from rabbit, dog, and rat in vivo models.
引用
- Dini C, Nagay BE, Magno MB, et al. Photofunctionalization as a suitable approach to improve the osseointegration of implants in animal models-A systematic review and meta-analysis. Clin Oral Implants Res. 2020. PMID: 32564392. doi:10.1111/clr.13627
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。