文献速递牙体牙髓病

超声检查检测牛下颌骨模拟根尖周骨病变的离体研究

Ultrasound examination for the detection of simulated periapical bone lesions in bovine mandibles: an ex vivo study.
PubMed 文献 · Int Endod J · 2020-07-09

该离体研究评估超声检查(USE)在牛下颌骨皮质骨板未完全侵蚀时检测人工骨缺损的准确性,并确定阻挡超声波的皮质骨最小厚度。结果显示USE灵敏度97.3%、阴性预测值89%,特异度和阳性预测值均为满分,ROC曲线下面积准确度97.8%,观察者间和观察者内一致性高。结论认为USE检测牛下颌骨内人工病变高度准确可靠,与皮质骨板厚度或是否存在无关。

要点

  • USE检测牛下颌骨人工骨缺损灵敏度97.3%,准确度97.8%。
  • USE特异度和阳性预测值均为满分,阴性预测值89%。
  • 观察者间Kappa值0.86和0.89,观察者内Kappa值0.92。

核心结论

  • USE检测牛下颌骨内人工病变高度准确可靠,与皮质骨板厚度或是否存在无关。

研究设计与样本

  • 阴性对照无骨内缺损,阳性对照为直径2 mm穿透颊侧皮质骨板的人工病变。
  • 实验组包括皮质骨板减薄至不同厚度下的小(2 mm)和大(5 mm)人工缺损,以及不涉及皮质骨板的小(2 mm)和大(5 mm)人工缺损。
  • USE扫描后由三名盲法检查者判读,分析灵敏度、特异度、预测值和ROC曲线。

主要发现

  • USE灵敏度97.3%,阴性预测值89%,特异度和阳性预测值均为满分。
  • ROC曲线分析显示准确度97.8%。
  • 第一次和第二次检查的Kappa值分别为0.86和0.89,观察者间一致性很高。
  • 观察者内一致性也高,Kappa值0.92。
  • 超声诊断与牛下颌骨解剖块中人工骨内病变存在与否显著相关(P < 0.0001)。

临床怎么用

  • USE可作为检测牛下颌骨内骨病变的准确可靠方法,不受皮质骨板厚度或是否存在影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate the accuracy of ultrasound examination (USE) for the detection of artificial bone defects in bovine mandibles in the absence of complete erosion of the cortical bone plate and to determine the minimum cortical thickness that constitutes a barrier for ultrasound waves. METHODOLOGY: Sixty bovine mandibular anatomical blocks were harvested and uniformly distributed amongst six experimental groups. The negative control consisted of blocks with no intra-bony defects, whereas the positive control consisted of blocks with an artificial lesion of 2 mm diameter that perforated the buccal cortical bone plate. Two experimental groups comprised blocks with small (2 mm) and large (5 mm) artificial defects created under a cortical plate thinned to varying thicknesses. Two additional groups had small (2 mm) and large (5 mm) artificial defects that did not involve the cortical plate. After USE, the scans were saved and submitted to three blinded examiners. Sensitivity, specificity, predictive values and receiver-operating characteristics (ROC) were analysed. The significance of the findings (P < 0.05) was appraised using the chi-square statistics with the Yates correction, whilst the intra- and inter-examiner agreements were evaluated through Kappa statistics. RESULTS: USE was associated with high sensitivity (97.3%) and negative predictive value (89%), and a perfect score for specificity and positive predictive value. The ROC curve analysis revealed an accuracy of 97.8%. The k-values were 0.86 and 0.89 for the first and second examinations, respectively, demonstrating very high inter-observer agreement. The intra-observer agreement was also high (k-value = 0.92). A significant correlation between the echographic diagnosis and the presence or absence of artificial intraosseous lesions in the anatomical blocks of bovine mandibles was observed (P < 0.0001). CONCLUSIONS: USE was highly accurate and reliable for the detection of artificial lesions within bovine mandibles, regardless of the thickness or presence of the cortical plate.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Musu D, Cadeddu Dessalvi C, Shemesh H, et al. Ultrasound examination for the detection of simulated periapical bone lesions in bovine mandibles: an ex vivo study. Int Endod J. 2020. PMID: 32531801. doi:10.1111/iej.13346

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。