邻牙金属桩修复对CBCT检测模拟性牙根内吸收的影响
本研究评估邻牙金属桩产生的伪影对CBCT检测模拟性牙根内吸收(IRR)的影响,并验证金属伪影减少(MAR)的作用。对14颗前磨牙在OP300 Maxio设备上分别在无MAR和有MAR条件下扫描,置于人下颌骨牙槽窝中分三种邻牙条件:无邻牙对照、单侧邻牙金属桩修复、双侧邻牙金属桩修复。五位口腔放射科医生采用5分制评分。结果显示仅双侧邻牙均有金属桩且不使用MAR时诊断性能显著下降,激活MAR可改善性能;灵敏度在双侧修复牙存在时显著降低,特异度不受影响。
要点
- 单侧邻牙金属桩修复不显著影响CBCT对IRR的诊断值。
- 双侧邻牙金属桩修复且不用MAR时ROC曲线下面积显著低于对照。
- 双侧修复牙存在时灵敏度显著降低,MAR不能恢复。
核心结论
- 仅当双侧邻牙均以金属桩修复时,CBCT检测IRR才受伪影损害。
- 此情形下激活MAR可改善该诊断任务的性能。
研究设计与样本
- 对14颗前磨牙在OP300 Maxio设备上于IRR模拟前后分别扫描,有/无MAR。
- 每颗牙置于人下颌骨牙槽窝中,分三种条件扫描:无邻牙对照、单侧邻牙金属桩修复、双侧邻牙金属桩修复。
- 五位口腔放射科医生用5分制评分检测IRR,采用双因素方差分析(α=0.05)比较诊断值。
主要发现
- 单侧邻牙金属桩修复对IRR检测诊断值无显著影响(P>0.05)。
- 双侧邻牙金属桩且不用MAR时,ROC曲线下面积(Az)显著低于对照(P=0.0182)。
- 此情形下应用MAR使Az升高,与对照及单侧修复牙组差异不显著(P>0.05)。
- 双侧修复牙存在时灵敏度显著降低,无论是否应用MAR(P=0.0379)。
- 特异度不受所测试条件影响(P>0.05)。
临床怎么用
- 当双侧邻牙均有金属桩修复时,CBCT检测IRR应激活MAR。
- 双侧邻牙金属桩修复时需注意灵敏度下降,避免漏诊IRR。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To assess the influence of artefacts generated by metal posts on the detection of simulated internal root resorption (IRR) in adjacent teeth using cone-beam computed tomography (CBCT) and to verify the impact of metal artefact reduction (MAR) on these cases. METHODOLOGY: CBCT images of 14 premolar teeth were acquired before and after IRR simulation using chemical and mechanical procedures, in an OP300 Maxio unit, with and without MAR. Each tooth was placed in the socket of a human mandible and scanned under three different conditions: (i) without adjacent teeth - control group; (ii) distal adjacent tooth restored with metal post; and (iii) with both adjacent teeth restored with metal post. Five oral radiologists scored the IRR detection using a 5-point scale. Diagnostic values were obtained for the tested groups and compared using two-way analysis of variance (α = 0.05). RESULTS: The presence of a single adjacent tooth restored with metal post did not significantly influence the diagnostic values for IRR detection (P > 0.05). The presence of both adjacent teeth with metal posts, without MAR application, was associated with a significantly lower area under the ROC curve (Az) compared to the control (P = 0.0182). In this case, the application of MAR increased Az, leading to nonsignificant differences from the control group and the group with one adjacent restored tooth (P > 0.05). Sensitivity decreased significantly when two adjacent restored teeth were present, regardless of MAR application (P = 0.0379). Specificity was not affected by the conditions tested (P > 0.05). CONCLUSION: CBCT detection of IRR was impaired by artefacts only when both adjacent teeth restored with metal posts were present. In such cases, activation of MAR improved the performance on this diagnostic task.
引用
- Gaêta-Araujo H, Nascimento EHL, Oliveira-Santos N, et al. Influence of adjacent teeth restored with metal posts in the detection of simulated internal root resorption using CBCT. Int Endod J. 2020. PMID: 32535964. doi:10.1111/iej.13348
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。