四根管上颌磨牙使用WaveOne Gold系统的预备顺序影响
本研究评估四根管上颌磨牙使用WaveOne Gold Primary(WOG 25.07)时预备顺序对体积变化、器械形变、循环疲劳和预备时间的影响。将48颗离体牙按起始顺序分4组,并通过显微CT和扫描电镜评估。结果显示顺序不影响体积变化和预备时间,但显著影响器械形变,其中MB-DB-P-MB2顺序器械形变最小。
要点
- 预备顺序不影响根管体积变化和预备时间(P > .05)。
- 预备顺序显著影响器械形变,P-MB2-MB-DB组形变大于MB-DB-P-MB2组。
- 为减少器械形变,推荐采用MB-DB-P-MB2预备顺序。
核心结论
- 根管预备顺序影响器械形变,但不影响WOG系统的体积变化和预备时间。
- 为最小化器械形变,推荐预备顺序为MB-DB-P-MB2。
研究设计与样本
- 离体牙实验,选取48颗永久性人四根管上颌磨牙。
- 按预备起始顺序分为4组:MB-DB-P-MB2;DB-P-MB2-MB;P-MB2-MB-DB;MB2-MB-DB-P。
- 使用显微CT扫描测量预备前后根管体积,扫描电镜评估器械磨损和形变,记录主动操作时间,显著性水平5%。
主要发现
- 各组间根管体积变化和预备时间无统计学显著差异(P > .05)。
- 器械形变存在统计学显著差异,P-MB2-MB-DB组器械形变大于MB-DB-P-MB2组。
关键数值与推荐
- 使用WaveOne Gold Primary(WOG 25.07)进行预备。
- 体积变化和预备时间组间比较P > .05,无显著差异。
- 器械形变组间比较有显著差异,P-MB2-MB-DB组形变大于MB-DB-P-MB2组。
临床怎么用
- 临床使用WOG系统预备四根管上颌磨牙时,建议采用MB-DB-P-MB2顺序以减少器械形变。
- 预备顺序对体积变化和操作时间无显著影响,可根据临床习惯调整。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to evaluate the effect of the order of preparation of four-canal maxillary molars on volume variation, instrument deformation, cyclic fatigue, and preparation time by using the WaveOne Gold Primary (WOG 25.07). METHODS: We selected 48 permanent, human, four-canal maxillary molars. The teeth were divided into 4 groups according to the order of initiation of the canal preparation sequence: (1) mesiobuccal (MB), distobuccal (DB), palatal (P), second mesiobuccal (MB2); (2) DB-P-MB2-MB; (3) P-MB2-MB-DB and (4) MB2-MB-DB-P. Pre- and post-preparation microtomography scanning was performed to obtain initial and final canal volume measurements. The instruments were also evaluated by using scanning electron microscopy to determine the wear and deformation present after use. The active instrumentation time was also recorded. The data were statistically compared by using a significance level of 5%. RESULTS: No statistically significant difference was found between groups for volume variation and time of preparation of the canals with the WOG system (P > .05); however, a statistically significant difference was observed in the deformation of the instruments. In the comparison between the groups for MB-DB-P-MB2 and P-MB2-MB-DB, the latter presented greater deformation of the instruments. CONCLUSIONS: Root canal preparation sequence affected deformation of the instruments but did not influence the volume variation or the canal preparation time with the WOG system. To minimize instrument deformation, the preparation order should be MB-DB-P-MB2.
引用
- Alberton CS, Tomazinho FSF, Calefi PS, et al. Influence of the Preparation Order in Four-Canal Maxillary Molars with WaveOne Gold System. J Endod. 2020. PMID: 32531311. doi:10.1016/j.joen.2020.05.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。