文献速递牙体牙髓病

往复与偏心旋转镍钛系统根管预备的微CT比较

Assessment of Mechanical Root Canal Preparation with Centric Reciprocating or Eccentric Rotary Kinematics: A Micro-computed Tomographic Study.
PubMed 文献 · J Endod · 2020-06-18

本研究通过微计算机断层扫描比较Reciproc往复系统与XP-endo Shaper偏心旋转系统对下颌磨牙近中根管的预备效果。结果显示XP-endo Shaper组总根管及颈、中三分之一未接触壁面积显著更低(P<.05),且总根管及中、根尖三分之一硬组织碎屑体积显著更低。两组牙本质去除量、根管体积和表面积增加无显著差异(P>.05)。

要点

  • XP-endo Shaper较Reciproc接触更多根管壁,未接触壁面积更低。
  • XP-endo Shaper组硬组织碎屑体积显著低于Reciproc组。
  • 两系统均无法完全预备根管,牙本质去除量无显著差异。

核心结论

  • XP-endo Shaper较Reciproc接触更多根管壁且残留硬组织碎屑更少,但两者均无法完全预备根管。

主要发现

  • XP-endo Shaper组总根管、颈三分之一和中三分之一的未接触壁面积显著低于Reciproc组(P<.05)。
  • Reciproc组总根管、中三分之一和根尖三分之一的硬组织碎屑体积显著高于XP-endo Shaper组。
  • 两组牙本质去除量、根管体积增加量和表面积增加量均无显著差异(P>.05)。

临床怎么用

  • 在需要更全面根管壁接触和更少硬组织碎屑残留时,可优先考虑XP-endo Shaper系统。
  • 无论使用哪种系统,均应辅以冲洗等措施以弥补器械无法完全预备根管的局限。

局限性

  • 本研究为离体牙实验,样本量较小(每组12颗),结果需临床研究进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to compare, using micro-computed tomographic imaging, the preparation of mesial canals of mandibular molars with the Reciproc (VDW GmbH, Munich, Germany) and XP-endo Shaper (FKG, La Chaux-de-Fonds, Switzerland) systems, evaluating changes in dentin and canal volume, the percentage of untouched walls, the volume of accumulated hard tissue debris, and root canal deviation in the apical third. METHODS: Twenty-four mandibular molars with 2 mesial root canals and a single foramen were anatomically paired and divided into 2 experimental groups (n = 12) according to the system used. The specimens were scanned before and after preparation with the SkyScan 1176 microtomographic scanner (Bruker-microCT, Kontich, Belgium) at a resolution of 17.42 μm. The resulting data were statistically compared at a significance level of 5% using the Student t test and the Mann-Whitney test. RESULTS: A significant difference was observed in the untouched surface area for the total canal and the cervical and middle thirds, with the lowest untouched surface area in the XP-endo Shaper group (P < .05). The volume of accumulated hard tissue debris was significantly higher in the Reciproc group in the total canal as well as in the middle and apical thirds. There was no significant difference between the groups regarding the volume of dentin removed or the increase in canal volume and surface area (P > .05). CONCLUSIONS: The XP-endo Shaper touched more walls and left less accumulated hard tissue debris in the root canal system than the Reciproc group. Although the XP-endo Shaper showed superior results, neither system was able to fully prepare the root canal.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Fernandes POF, Freire LG, Iglecias EF, et al. Assessment of Mechanical Root Canal Preparation with Centric Reciprocating or Eccentric Rotary Kinematics: A Micro-computed Tomographic Study. J Endod. 2020. PMID: 32565335. doi:10.1016/j.joen.2020.06.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。