文献速递牙体牙髓病

载体与搅拌方法对氢氧化钙糊剂牙本质小管渗透的影响

Effect of Vehicle and Agitation Methods on the Penetration of Calcium Hydroxide Paste in the Dentinal Tubules.
PubMed 文献 · J Endod · 2020-05-18

结果显示距根尖2mm处各因素无显著差异,而5mm处丙二醇载体的渗透百分比显著更高。

要点

  • 距根尖5mm处,丙二醇载体的氢氧化钙渗透百分比显著高于蒸馏水。
  • 距根尖2mm处,不同载体和搅拌方法间渗透无显著差异。
  • 临床选择载体时需考虑其对氢氧化钙牙本质小管渗透的影响。

核心结论

  • 在距根尖5mm处,载体类型影响氢氧化钙糊剂在牙本质小管中的渗透,丙二醇载体效果更好。

主要发现

  • 距根尖2mm处,各研究因素间无统计学显著差异(P > .05)。
  • 距根尖5mm处,不同载体间渗透百分比有显著差异(P < .05),丙二醇组均值更高。

关键数值与推荐

  • 分组包括:丙二醇+Lentulo、丙二醇+Lentulo+超声、丙二醇+Lentulo+声波、蒸馏水+Lentulo、蒸馏水+Lentulo+超声、蒸馏水+Lentulo+声波。
  • 氢氧化钙糊剂用荧光素钠染料调制,充填根管后取距根尖2mm和5mm处1mm厚切片,共聚焦激光扫描显微镜扫描,ImageJ分析渗透百分比和最大渗透深度。
  • 统计采用单因素方差分析和Tukey HSD事后检验。

临床怎么用

  • 在需要氢氧化钙渗透至根尖5mm区域时,可优先考虑使用丙二醇作为载体。

局限性

  • 离体研究结果需结合临床实际情况判断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this ex vivo study was to analyze the effect of different vehicles combined with agitation methods on the penetration of calcium hydroxide (CH) paste in the dentinal tubules. METHODS: Sixty freshly extracted, single-rooted human premolars were prepared using WaveOne Gold (Dentsply Sirona, York, PA) and randomized into 6 experimental groups (n = 10) according to the vehicle and method of paste agitation as follows: propylene glycol (PG) + Lentulo, PG + Lentulo + ultrasound, PG + Lentulo + sonic, distilled water (DW) + Lentulo, DW + Lentulo + ultrasonic, and DW + Lentulo + sonic. The CH paste was manipulated with sodium fluorescein dye and was inserted to completely fill the root canal. Two 1-mm thick sections at 2 mm and 5 mm from the apex of each root were obtained. The sections were scanned using confocal laser scanning microscopy, and the images were analyzed using ImageJ software (Bethesda, MD) to calculate the percentage penetration and maximum penetration depth of CH paste. Statistical analysis was performed using 1-way analysis of variance and Tukey honestly significant difference post hoc tests. RESULTS: No statistically significant differences between study factors at a distance of 2 mm from the apex were observed (P > .05). However, at 5 mm, a significant difference between the vehicles (P < .05) in percentage penetration was demonstrated with higher means for PG. CONCLUSIONS: Vehicles interfered with the penetration of CH in the dentinal tubules at 5 mm from the apex with better results for PG.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. de Almeida Barbosa M, de Oliveira KV, Dos Santos VR, et al. Effect of Vehicle and Agitation Methods on the Penetration of Calcium Hydroxide Paste in the Dentinal Tubules. J Endod. 2020. PMID: 32439224. doi:10.1016/j.joen.2020.03.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。