三种往复单锉镍钛系统对单弯和双弯根管成形能力的微计算机断层扫描评价
该研究采用微计算机断层扫描评估S1 Plus Standard、WaveOne Gold Primary和Reciproc R25三种单锉往复镍钛系统对中度弯曲下颌磨牙单弯和双弯根管的预备效果。结果显示各组间所有参数均无显著差异,弯曲类型对参数无显著影响,但所有组根管偏移从根尖向冠方显著增加,且多朝向根分叉区。
要点
- 三种往复单锉镍钛系统对中度弯曲根管的成形效果无显著差异。
- 单弯和双弯根管类型对成形参数无显著影响。
- 根管偏移从根尖向冠方显著增加,多朝向根分叉区。
核心结论
- 三种镍钛系统预备后根管尺寸变化无显著差异。
- 弯曲类型对所有测试参数无显著影响。
研究设计与样本
- 牙齿按弯曲度(15°-40°)、半径(≤18 mm)和弯曲类型匹配分为3组(n=25)。
主要发现
- 各组间根管体积和表面积变化、未成形根管壁百分比、结构模型指数、根管偏移和居中率均无显著差异。
- 所有组根管偏移从根尖向冠方显著增加,多数朝向根分叉区。
临床怎么用
- 三种往复单锉镍钛系统均可用于中度弯曲根管预备,成形效果相当。
- 操作时需注意根管偏移从根尖向冠方增加且多朝向根分叉区。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: We performed a micro-computed tomographic assessment of the preparation of moderately single- and double-curved root canals using 3 single-file reciprocating nickel-titanium systems: S1 Plus Standard (Sendoline, Täby, Sweden), WaveOne Gold Primary (Dentsply Sirona, Ballaigues, Switzerland), and Reciproc R25 (VDW, Munich, Germany). METHODS: Seventy-five moderately curved mandibular molars with 2 separate mesial root canals were assigned to 3 experimental groups (n = 25) (ie, S1 Plus Standard, WaveOne Gold Primary, and Reciproc 25 groups) by forming matched triples according to curvature (15°-40°), radius (≤18 mm), and type of curvature (single or double curved). Teeth were scanned before and after root canal preparation with a resolution of 10.5 μm using micro-computed tomographic imaging (Bruker SkyScan 1272; Bruker microCT, Kontich, Belgium). The following parameters were assessed: changes in root canal volume and surface area, percentage of unshaped canal walls, structure model index, canal transportation, and centering ratio. Data were analyzed using 2- and 3-way analysis of variance with Tukey and Scheffé post hoc tests (significance level of 5%). RESULTS: No significant differences among groups were observed concerning all parameters. The type of curvature had no significant effect on all tested parameters. Within all experimental groups, canal transportation increased significantly from the apical to the coronal region, of which the majority was directed toward the furcational area. CONCLUSIONS: Preparation with the 3 nickel-titanium systems did not result in significantly different dimensional changes, and there was no significant effect of the type of curvature on all tested parameters.
引用
- Haupt F, Pult JRW, Hülsmann M, et al. Micro-computed Tomographic Evaluation of the Shaping Ability of 3 Reciprocating Single-File Nickel-Titanium Systems on Single- and Double-Curved Root Canals. J Endod. 2020. PMID: 32464140. doi:10.1016/j.joen.2020.05.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。