文献速递牙体牙髓病

新型镍钛根管锉的力学性能:静态与动态测试

Mechanical Properties of a Novel Nickel-titanium Root Canal Instrument: Stationary and Dynamic Tests.
PubMed 文献 · J Endod · 2020-05-07

本研究在体外比较新型TruNatomy(TN)成形锉与常规ProTaper Next(PTN)的力学性能。测试疲劳极限(每尺寸n=20)、扭转阻力(每尺寸n=6)及模拟成形(每尺寸n=6)。结果显示TN各尺寸疲劳抗力及可靠性显著优于PTN,扭转极限相似但断裂扭转角更大;模拟成形中无器械折断,TN工作扭矩与旋入力显著更低。

要点

  • TN各尺寸疲劳抗力及可靠性显著优于PTN。
  • TN与PTN扭转极限相似,但TN断裂扭转角更大。
  • 模拟成形中无器械折断,TN工作扭矩与旋入力显著更低。

核心结论

  • TN比PTN更抗疲劳,且工作扭矩与旋入力显著更可预测。

研究设计与样本

  • 体外研究比较TN与PTN不同尺寸的疲劳极限(每尺寸n=20)、扭转阻力(每尺寸n=6)及模拟成形(每尺寸n=6)。
  • 疲劳测试采用含锥形模拟弯曲根管(角度75°、半径5 mm)的夹具,并附热探头与冷却气流(至少2 bars)使温升低于2°C。
  • 扭转阻力按ISO 3630-1测试;模拟成形在标准化J形弯曲根管塑料块中由计算机控制设备实时记录扭矩与力。
  • 断裂模式用扫描电子显微镜评估,统计采用参数统计与Weibull分析。

主要发现

  • TN测试尺寸的疲劳抗力与可靠性显著优于PTN。
  • TN与PTN扭转极限相似,但TN断裂时扭转角更大。
  • 模拟成形中无器械折断,TN的工作扭矩与旋入力显著低于PTN。

临床怎么用

  • TN在弯曲根管成形中可能更耐疲劳,且工作扭矩与旋入力更低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to describe the mechanical properties both in stationary and dynamic conditions in vitro of the novel TruNatomy (TN; (Dentsply Sirona, Ballaigues, Switzerland) shaping files and compare them with a conventional rotary system, ProTaper Next (PTN, Dentsply Sirona). METHODS: Different sizes of 2 types of rotary files, TN and PTN, were compared for their fatigue limit (n = 20 each size) and torsional resistance (n = 6 each size) and subjected to simulated shaping (n = 6 each size). Fatigue limits were determined in a novel fixture including a tapered simulated curved canal (angle = 75°, radius = 5 mm) with a thermal probe and a cooling airstream (minimum of 2 bars) attached to keep the temperature rise below 2°C. Torsional resistance was tested according to ISO 3630-1. Shaping was simulated in plastic blocks with standardized J-shaped curved root canals in a computer-controlled device to register real-time torque and force. Fracture patterns were assessed using scanning electron microscopy. Parametric statistics and Weibull analysis were used to compare groups. RESULTS: The tested sizes for TN were significantly more fatigue resistant and reliable compared with PTN; torsional limits were similar, but twist angles at failure were larger for TN. No instruments fractured during simulated shaping, and the working torque and the threading-in force were significantly lower for TN. CONCLUSIONS: This study showed the mechanical properties of both TN and PTN in terms of fatigue limit and torsional resistance and compared them with simulated canal shaping. TN was found to be more fatigue resistant and showed significantly more predicable torque and threading-in force compared with PTN.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Peters OA, Arias A, Choi A, et al. Mechanical Properties of a Novel Nickel-titanium Root Canal Instrument: Stationary and Dynamic Tests. J Endod. 2020. PMID: 32389382. doi:10.1016/j.joen.2020.03.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。