牙本质切割效率对扭矩控制旋转器械侧向力的影响
本研究在牛牙本质中比较了奥氏体(ProTaper Universal)与含马氏体相(ProTaper Gold)镍钛旋转器械的侧向切割效率,并监测模拟前磨牙根管预备时的根管内侧向力。结果显示马氏体器械切割效率显著更高(t检验,P < 0.05),但侧向力无差异;侧向力峰值随渐进锥度器械接近全工作长度而出现,且S1器械产生最大侧向力(anova/Tukey's HSD,P < 0.05)。结论认为侧向力主要受器械几何设计影响,而非牙本质切割效率。
要点
- 马氏体镍钛器械侧向切割效率显著高于奥氏体器械(P < 0.05)。
- 切割效率差异未影响根管预备时的侧向力。
- S1器械在全长序列中产生最高侧向力(P < 0.05)。
核心结论
- 牙本质切割效率不影响扭矩控制旋转器械产生的侧向力,侧向力主要受器械几何设计影响。
研究设计与样本
- 实验研究,在牛牙本质盘(n = 6)中比较奥氏体(ProTaper Universal)与马氏体相(ProTaper Gold)器械的侧向切割效率,并用数字显微镜研究器械形状。
- 在由牛切牙根制成的模拟前磨牙(n = 9)中,使用配备扭矩控制牙髓马达/手机的测试装置监测根管内侧向力,根管标准化窄径、长16 mm。
- 数据采用参数统计,α误差 = 0.05。
主要发现
- 两种器械的几何设计相同。
- 马氏体镍钛旋转器械的侧向切割效率显著高于奥氏体 counterparts(t检验,P < 0.05)。
- 切割效率差异未影响模拟前磨牙根管预备时产生的侧向力。
- 渐进锥度器械在接近全工作长度时产生侧向力峰值。
- 即使预备了滑行路径,全长序列中第一个器械(S1)产生最高侧向力(anova/Tukey's HSD,P < 0.05)。
临床怎么用
- 选择旋转器械时,侧向力风险应更多考虑器械几何设计而非切割效率。
- 使用渐进锥度器械接近全工作长度时需注意侧向力峰值。
- 即使已预备滑行路径,S1器械仍可能产生最高侧向力,操作时应谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To study the impact of dentine cutting efficiency of rotary instruments on the lateral force they create when instrumenting simulated root canals in bovine dentine. METHODOLOGY: Lateral cutting efficiency of austenitic files (ProTaper Universal) was compared to that of counterparts of a reported identical geometrical design with a martensite phase component (ProTaper Gold) in bovine dentine disks (n = 6). Instrument shapes were studied using digital microscopy. The intracanal lateral force exerted by the two systems in simulated premolars (n = 9) made from bovine incisor roots containing a standardized narrow root canal of 16 mm length was monitored using a testing apparatus equipped with a torque-controlled endodontic motor/handpiece. Data were compared using parametric statistics, alpha error = 0.05. RESULTS: The geometrical design of the two systems under investigation was found to be identical. The martensitic nickel-titanium rotary files had a significantly (t-test, P < 0.05) higher lateral cutting efficiency than austenitic counterparts. This difference, however, did not impact the lateral force that was created when instrumenting simulated premolar root canals. Furthermore, lateral force peaks were generated with the progressively tapered instruments under investigation towards the full working length. Even though a glide path was prepared, the first instrument in the full-length sequence (S1) created the highest lateral force (anova/Tukey's HSD, P < 0.05). CONCLUSIONS: The current experimental set-up allows the study of the lateral force generated during root canal instrumentation. This force was not influenced by the dentine cutting efficiency of the instruments under investigation, but rather by their geometrical design.