PUFA指数与根尖周指数筛查牙髓病的信度与准确性比较
本研究为横断面研究,连续纳入165名受试者,比较PUFA指数与根尖周指数(PAI)在筛查牙髓及根尖周疾病中的诊断准确性。结果显示PUFA指数在牙髓和根尖诊断中的敏感性分别为67.6%和87.7%,特异性分别为99.8%和95.4%,其诊断准确性显著优于PAI(P < .05)。
要点
- PUFA指数筛查牙髓病的敏感性67.6%、特异性99.8%,准确性优于PAI。
- PUFA指数筛查根尖周病的敏感性87.7%、特异性95.4%,准确性优于PAI。
- PUFA与PAI的检查者间信度分别为0.87和0.80,重复性较好。
核心结论
- PUFA指数可用于牙髓及根尖周疾病的筛查,但存在一定局限性。
研究设计与样本
- 横断面研究,采用连续抽样,共纳入165名受试者。
- 每位受试者接受PUFA指数筛查、全景片PAI评估及全面临床检查以确定牙髓和根尖诊断。
- 共评估4115颗牙,其中16.2%(n=666)诊断为牙髓病,7.9%(n=325)诊断为根尖周病。
主要发现
- PUFA指数与PAI的检查者间信度分别为0.87和0.80。
- PUFA指数与PAI的检查者内信度分别为0.83/0.76和0.75/0.72。
- 牙髓诊断:PUFA指数敏感性67.6%、特异性99.8%;PAI敏感性41.7%、特异性99.2%。
- 根尖诊断:PUFA指数敏感性87.7%、特异性95.4%;PAI敏感性75.4%、特异性98.4%。
- PUFA指数在牙髓和根尖诊断中的准确性均显著优于PAI(P < .05)。
临床怎么用
- PUFA指数可作为牙髓及根尖周疾病的筛查工具,但需结合临床检查确认。
局限性
- PUFA指数用于筛查牙髓和根尖周疾病时存在一定局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The pulpal involvement, ulceration, fistula, and abscess (PUFA) index was developed to screen for the clinical consequences of untreated dental caries. The aim of this study was to compare the diagnostic accuracy of the PUFA index and the periapical index (PAI) in identifying pulpal and periapical diseases. METHODS: A cross-sectional study was conducted using consecutive sampling. Each participant went through screening using the PUFA index, orthopantomography assessment using PAI, and comprehensive clinical examination to derive pulpal and apical diagnoses. The outcomes were dichotomized. Reliability was estimated using the Cohen kappa coefficient. Sensitivity, specificity, and predictive values were calculated. The area under the receiver operating characteristic curve was compared using the chi-square test. RESULTS: A total of 165 participants were examined, 98.2% of whom had a decayed, missing, or filled tooth index >0. Of 4115 teeth assessed, 16.2% (n = 666) were diagnosed with pulpal disease and 7.9% (n = 325) with periapical disease. Interexaminer reliability for the PUFA index and PAI was 0.87 and 0.80, respectively. Intraexaminer reliability was 0.83 and 0.76 for the PUFA index and 0.75 and 0.72 for PAI. For pulpal diagnosis, the sensitivity of the PUFA index and PAI was 67.6% and 41.7%, respectively; the specificity of the PUFA index and PAI was 99.8% and 99.2%, respectively. For apical diagnosis, the sensitivity of the PUFA index and PAI was 87.7% and 75.4%, respectively; the specificity of the PUFA index and PAI was 95.4% and 98.4%, respectively. The PUFA index is statistically more accurate than PAI for pulpal diagnosis and apical diagnosis (P < .05). CONCLUSIONS: The PUFA index can be used in screening for pulpal and periapical diseases with some limitations.
引用
- Teh LA, Abdullah D, Liew AKC, et al. Evaluation of Pulpal Involvement, Ulceration, Fistula, and Abscess Index and Periapical Index in Screening for Endodontic Disease: Reliability and Accuracy. J Endod. 2020. PMID: 32279884. doi:10.1016/j.joen.2020.02.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。