文献速递牙体牙髓病

基于微CT和计算机模拟方法为牙髓实验室比较研究创建均衡实验组的新提案

Creation of well-balanced experimental groups for comparative endodontic laboratory studies: a new proposal based on micro-CT and in silico methods.
PubMed 文献 · Int Endod J · 2020-04-15

该研究提出一种利用微计算机断层扫描(micro-CT)技术选择解剖学匹配牙齿的新方法。研究选取60颗单根管下颌切牙,分为三组,每组10对,分别采用随机选择、X线片配对和micro-CT配对。结果显示micro-CT配对组解剖学相关性显著优于其他两组(P < 0.05),能更好地控制牙齿形态差异带来的混杂效应。

要点

  • micro-CT配对组100%样本的根管宽高比(AR)相关性为强或非常强。
  • micro-CT配对法相关系数显著高于X线片法和随机法(P < 0.05)。
  • X线片法与随机法之间无显著差异(P > 0.05)。

核心结论

  • 使用micro-CT能更好地控制牙齿形态解剖变异对配对设计实验结果的混杂效应。

研究设计与样本

  • 选取60颗单根管下颌切牙,每组10对,分三组比较随机选择、X线片配对和micro-CT配对方法。
  • micro-CT扫描像素大小为14.25 μm,基于根管宽高比(AR)、体积和三维几何形态进行配对。

主要发现

  • micro-CT组100%样本的AR值相关性为强(80%)或非常强(20%)。
  • X线片组仅20%配对呈强相关,30%弱相关,30%可忽略相关。
  • 随机组30%配对呈非常强相关,50%弱或可忽略相关。
  • micro-CT法相关系数与其他两组差异显著(P < 0.05),X线片法与随机法间无差异(P > 0.05)。

关键数值与推荐

  • micro-CT组配对选择的效应量η²为0.99,X线片组为0.67,随机组为0.66。

临床怎么用

  • 在牙髓实验室配对设计研究中,可采用micro-CT扫描基于根管AR、体积和三维几何形态进行牙齿配对,以均衡实验组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To introduce a new method to select anatomically matched teeth using micro-computed tomographic (micro-CT) technology. METHODOLOGY: Single-rooted mandibular incisors with a single root canal (n = 60) were selected and distributed into three experimental groups according to the method used for matching 10 pairs of teeth in each group. In group 1, the pairs of mandibular incisors were randomly selected from a pool of teeth. In group 2, teeth were paired based on the measurement of canal width 5 mm from the root apex using radiographs taken from buccolingual and mesiodistal directions. In group 3, teeth were scanned (pixel size of 14.25 μm) and pair-matched based on the anatomical aspects of the root canal, named aspect ratio (AR), volume and three-dimensional canal geometry. After allocating the specimens into groups 1 and 2, the teeth were scanned and the canal morphology evaluated as in group 3. A bivariate Pearson's regression analysis was performed correlating the individual AR values of each pair, and the correlation coefficient was used to estimate the strength of the pair-matching process. One-way anova post hoc Tukey's tests were applied for pairwise comparisons at a significance level of 5%. RESULTS: The micro-CT revealed that 100% of the samples had strong (80%) or very strong (20%) correlations with respect to AR values. Analysis of the radiographic method revealed strong correlation in two pairs (20%), but most of the samples had weak (30%) or negligible (30%) correlation coefficients. The randomization method resulted in three pairs (30%) with very strong correlations, whilst 50% had weak or negligible rates. A significant difference in correlation coefficients was observed in the micro-CT method compared to the other groups (P < 0.05), whilst no difference was detected between radiographic and randomized methods (P > 0.05). Eta-squared (η2 ) calculations demonstrated a very high effect size in the micro-CT group for selecting pairs (0.99) and lower effect sizes in the radiographic (0.67) and randomized (0.66) groups. CONCLUSIONS: Use of Micro-CT was able to provide better control of the confounding effect that anatomical variances in tooth morphology may have on the results in experiments with matched-pair design.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. De-Deus G, Simões-Carvalho M, Belladonna FG, et al. Creation of well-balanced experimental groups for comparative endodontic laboratory studies: a new proposal based on micro-CT and in silico methods. Int Endod J. 2020. PMID: 32159857. doi:10.1111/iej.13288

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。