文献速递牙体牙髓病

微计算机断层扫描评估4种热处理镍钛系统的根管偏移与中心定位能力

Micro-Computed Tomographic Evaluation of Canal Transportation and Centering Ability of 4 Heat-Treated Nickel-Titanium Systems.
PubMed 文献 · J Endod · 2020-03-11

结果显示4种系统均造成极小偏移且预备相对居中,HyFlex CM在根尖3 mm处偏移小于WaveOne Gold,在冠方7 mm舌侧偏移小于WaveOne Gold和OneCurve,各组中心定位比无统计学差异。

要点

  • 4种热处理镍钛系统均能安全预备根管,造成极小根管偏移且预备相对居中。
  • 根尖3 mm处HyFlex CM的根管偏移小于WaveOne Gold(P < .05)。
  • 冠方7 mm舌侧HyFlex CM偏移小于WaveOne Gold和OneCurve。

核心结论

  • 4种热处理镍钛系统均能安全预备根管,造成极小根管偏移并产生相对居中的预备。
  • 就根管偏移而言,HyFlex CM在根尖水平优于WaveOne Gold,在冠方水平优于WaveOne Gold和OneCurve。

研究设计与样本

  • 分组对应HyFlex CM、HyFlex EDM、WaveOne Gold和OneCurve四种根管预备系统。
  • 预备前后以19.9 μm分辨率进行X线微计算机断层扫描成像。
  • 在距根尖3 mm、5 mm、7 mm处分析根尖偏移与中心定位能力。
  • 采用单因素方差分析和Kruskal-Wallis检验进行组间统计比较,显著性水平设为5%。

主要发现

  • 在3 mm水平,HyFlex CM在颊侧和舌侧根管造成的根管偏移均小于WaveOne Gold(P < .05)。
  • 在7 mm水平舌侧根管,HyFlex CM的根管偏移小于WaveOne Gold和OneCurve。
  • 各组间平均中心定位比比较无统计学显著差异。

关键数值与推荐

  • 根管偏移与中心定位能力在距根尖3 mm、5 mm、7 mm三个水平评估,分别代表根尖、根中与冠方三分之一。
  • 统计学显著性水平设为5%。

临床怎么用

  • 对于需关注根尖或冠方偏移的病例,可参考HyFlex CM在相应水平偏移较小的结果选择预备系统。
  • 4种系统均可实现相对居中的预备,临床可依据其他因素综合选择。

局限性

  • 研究为离体牙实验,结果不能直接等同于临床性能。
  • 仅评估下颌磨牙近中根管,结论外推至其他牙位或根管形态需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study aimed to evaluate and compare canal transportation and centering ability of 4 different root canal preparation systems produced with thermal treatments by means of micro-computed tomographic imaging. METHODS: Eighty mesial canals of human extracted mandibular molars were selected based on similar morphologic parameters and were randomly assigned to 4 experimental groups (n = 20) according to the canal instrumentation technique: HyFlex CM (HCM [Coltène-Whaledent, Allstätten, Switzerland]), HyFlex EDM (HEDM [Coltène-Whaledent]), WaveOne Gold (WOG [Dentsply Sirona, Ballaigues, Switzerland]), and OneCurve (OC [Micro-Mega, Besancon, France]). The specimens were scanned before and after root canal preparation using X-ray micro-computed tomographic imaging at a resolution of 19.9 μm. Apical transportation and centering ability were then analyzed at 3 different levels: 3 mm, 5 mm, and 7 mm from the apex, representing the apical, midroot, and coronal thirds of the root, respectively. One-way analysis of variance and Kruskal-Wallis tests were used to statistically compare the groups. The significance level was set at 5%. RESULTS: HCM caused less canal transportation than WOG at the 3-mm level in both the buccal and lingual canals (P < .05). Also, HCM resulted in less canal transportation than WOG and OC at the 7-mm level regarding lingual canals. No statistically significant differences were recorded between the groups when the mean centering ratios were compared. CONCLUSIONS: The 4 evaluated systems safely prepared root canals causing minimal canal transportation and producing relatively centered preparations. In terms of canal transportation, HCM performed better than WOG at the apical level and better than WOG and OC at the coronal level.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Razcha C, Zacharopoulos A, Anestis D, et al. Micro-Computed Tomographic Evaluation of Canal Transportation and Centering Ability of 4 Heat-Treated Nickel-Titanium Systems. J Endod. 2020. PMID: 32171564. doi:10.1016/j.joen.2020.01.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。