文献速递牙体牙髓病儿童口腔

不同终末搅动技术对年轻恒牙冲洗液溢出量的体积分析

Volumetric Analysis of Irrigant Extrusion in Immature Teeth after Different Final Agitation Techniques.
PubMed 文献 · J Endod · 2020-03-02

本研究用15颗根尖孔开放的下颌前磨牙建立实验模型,比较6种终末搅动技术下冲洗液溢出体积。结果显示所有技术均导致冲洗液溢出,其中Eddy声波搅动组的溢出体积最高(17.19 mm³),与其他组差异有统计学意义(P < .05)。

要点

  • 所有终末搅动技术均导致冲洗液溢出根尖。
  • Eddy声波搅动组的溢出体积显著高于其他各组。
  • XP-endo Finisher组溢出体积最低(0.67 mm³)。

核心结论

  • 所有测试的终末搅动技术均导致冲洗液溢出根尖。
  • 使用Eddy进行声波搅动时冲洗液溢出量最高。

研究设计与样本

  • 实验研究,使用15颗长度14 mm、根尖孔开放的下颌前磨牙单根。
  • 按终末搅动技术分为6组:无搅动正压冲洗、Irrisonic超声、Irrisonic Power超声、Easy Clean机械、XP-endo Finisher机械、Eddy声波。
  • 用Eppendorf管填充琼脂固定牙齿并收集溢出液,以Ioditrast 76模拟冲洗液,显微CT计算溢出体积(mm³)。
  • 数据分析采用Kruskal-Wallis和Dunn检验,显著性水平5%。

主要发现

  • 溢出体积(mm³):XP-endo Finisher组0.67,无搅动组0.76,Irrisonic组2.28,Irrisonic Power组3.14,Easy Clean组3.15,Eddy组17.19。
  • Eddy组与其他各组比较差异有统计学意义(P < .05)。

临床怎么用

  • 在根尖孔开放的年轻恒牙中,使用Eddy声波搅动需警惕冲洗液溢出风险。
  • 选择终末搅动技术时应考虑其对冲洗液溢出的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to evaluate the volume of irrigant extrusion by different final agitation techniques in experimental models of immature teeth. METHODS: Fifteen single roots of mandibular premolars with a length of 14 mm and an open apex were used to form 6 groups according to the final agitation technique: group 1, positive pressure and no agitation; group 2, ultrasonic agitation with Irrisonic (Helse Dental Technology, Santa Rosa de Viterbo, Brazil); group 3, ultrasonic agitation with Irrisonic Power (Helse Dental Technology); group 4, mechanical agitation with Easy Clean (Easy Dental Equipment, Belo Horizonte, Brazil); group 5, mechanical agitation with XP-endo Finisher (FKG Dentaire, La Chaux-de-Fonds, Switzerland); and group 6, sonic agitation with Eddy (VDW, Munich, Germany). A prototype was made from an Eppendorf plastic tube filled with agar to fix the tooth and to collect the extruded irrigant. Ioditrast 76 (Justesa Imagen Mexicana, Tlalpan, Mexico) contrast solution was used to simulate the irrigant. The volume of irrigant extruded in cubic millimeters was calculated by micro-computed tomographic imaging. Data were analyzed using Kruskal-Wallis and Dunn tests with a significance level of 5%. RESULTS: The values for the volume of irrigant extruded were as follows: 0.67 (group 5), 0.76 (group 1), 2.28 (group 2), 3.14 (group 3), 3.15 (group 4), and 17.19 (group 6). There was a statistically significant difference (P < .05) when the values of group 6 were compared with those of the other groups. CONCLUSIONS: All techniques caused irrigant extrusion. The higher extrusion values occurred when sonic agitation was performed with the Eddy instrument.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Dos Reis S, Cruz VM, Hungaro Duarte MA, et al. Volumetric Analysis of Irrigant Extrusion in Immature Teeth after Different Final Agitation Techniques. J Endod. 2020. PMID: 32139265. doi:10.1016/j.joen.2020.01.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。