文献速递口腔修复与种植

比较体积稳定胶原基质与自体结缔组织移植物在种植位点增量的随机对照临床试验:重建体植入后3年数据

Randomized controlled clinical trial comparing implant sites augmented with a volume-stable collagen matrix or an autogenous connective tissue graft: 3-year data after insertion of reconstructions.
PubMed 文献 · J Clin Periodontol · 2020-01-01

这项随机对照临床试验在20例单颗种植位点应用体积稳定胶原基质(VCMX)或自体上皮下结缔组织移植物(SCTG),在重建体植入后随访3年,比较临床、影像学和轮廓测量结果。两组种植体周围软组织与骨水平保持健康,轮廓和软组织厚度变化极小,组间无显著差异。

要点

  • VCMX与SCTG在种植位点3年随访中软组织轮廓和厚度变化均很小。
  • 两组种植体周围软组织与骨水平在整个研究期间保持健康。
  • 患者报告结局(PROMs)组间及随时间均无显著差异。

核心结论

  • 先前接受VCMX或SCTG增量的种植位点,种植体周围组织轮廓及软组织厚度变化极小。

研究设计与样本

  • 随机对照临床试验,20例患者单颗种植位点随机应用VCMX或SCTG,在基线和重建体植入后6个月、1年及3年复查。

主要发现

  • 颊侧黏膜厚度从基线至3年:VCMX中位增加0.5 mm(Q1: -0.5; Q3: 1.25)(p = .281),SCTG中位增加0.8 mm(Q1: 0.0; Q3: 2.5)(p = .047),组间p = .303。
  • 颊侧软组织轮廓测量变化从基线至3年:VCMX中位减少-0.2 mm(Q1: -0.5; Q3: -0.1)(p = .039),SCTG中位减少-0.1 mm(Q1: -0.8; Q3: 0.1)(p = .020),组间p = .596。
  • 种植体周围软组织与骨水平在整个研究期间保持健康。
  • 患者报告结局(PROMs)组间及随时间均无显著差异。

临床怎么用

  • 对于单颗种植位点软组织增量,VCMX可作为SCTG的替代选择,3年随访时轮廓与厚度变化均很小且组间无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To assess mid-term clinical, radiographic and profilometric outcomes at implant sites, previously grafted with a volume-stable collagen matrix (VCMX) or an autogenous subepithelial connective tissue graft (SCTG). METHODS: VCMX or SCTG were randomly applied to single implant sites in 20 patients. Following abutment connection and insertion of final reconstructions (baseline), patients were re-examined at 6 months (6M), at 1 year (FU-1) and at 3 years (FU-3). Measurements included the following: clinical data, radiographic measurement of first bone to implant contact (fBIC), soft tissue thickness and volumetric outcomes. Non-parametric tests and estimates were applied for the statistical analysis. RESULTS: The median buccal mucosal thickness increased by 0.5 mm (Q1: -0.5; Q3: 1.25) (VCMX) (p = .281) and by 0.8 mm (Q1: 0.0; Q3: 2.5) (SCTG) (p = .047) between BL and FU-3 (intergroup p = .303). The profilometric changes of the buccal soft tissues demonstrated a median decrease between BL and FU-3 of -0.2 mm (Q1: -0.5; Q3: -0.1) (p = .039) for VCMX and a decrease of -0.1 mm (Q1: -0.8; Q3: 0.1) (p = .020) for SCTG, respectively (intergroup p = .596). Peri-implant soft tissues and bone levels remained healthy throughout the entire study period. PROMs did not show any significant differences between the groups nor significant changes over time. CONCLUSION: Minimal changes of the peri-implant tissue contour as well as of the soft tissue thickness were observed at implant sites previously grafted with VCMX or SCTG.

来源:J Clin Periodontol,查看原文。版权归原作者所有。

引用

  1. Thoma DS, Gasser TJW, Jung RE, et al. Randomized controlled clinical trial comparing implant sites augmented with a volume-stable collagen matrix or an autogenous connective tissue graft: 3-year data after insertion of reconstructions. J Clin Periodontol. 2020. PMID: 32096246. doi:10.1111/jcpe.13271

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。