支持性牙周治疗中替代或辅助机械清创方法的疗效:系统综述与荟萃分析
该系统综述与荟萃分析评估了牙周支持治疗(SPT)中替代或辅助专业机械菌斑清除(PMPR)的方法对附着丧失进展的疗效。纳入随机临床试验,主要结局为临床附着水平(CAL)相对基线的变化。结果显示常规PMPR(超声/手工器械联合或Er:Yag激光)预防CAL丧失效果相似,每日亚抗菌剂量多西环素(SDD)或辅助光动力疗法(PDT)未显著增强疗效;汇总CAL变化均值为-0.233 mm(95%CI:-1.065,0.598;p=.351),无统计学差异。证据等级较弱。
要点
- 常规PMPR(超声/手工联合或Er:Yag激光)预防CAL丧失效果相似。
- 每日SDD或辅助PDT未在PMPR基础上显著改善CAL。
- 汇总CAL变化均值-0.233 mm(95%CI:-1.065,0.598;p=.351),无统计学差异。
核心结论
- 弱证据表明,在接受3-4个月PMPR为基础SPT的牙周炎患者中,Er:Yag激光(替代)、SDD和PDT(辅助)相较于PMPR未产生更大的临床效果。
研究设计与样本
- 系统综述与荟萃分析,检索随机临床试验,主要结局为CAL相对基线变化。
主要发现
- 常规PMPR采用超声/手工器械联合或Er:Yag激光在预防CAL丧失方面效果相似。
- 以PMPR为基础的常规SPT方案可使CAL保持稳定,与每日SDD剂量无关。
- 对探诊深度≥4 mm位点重复进行辅助PDT未增强CAL获得幅度。
- 汇总CAL变化均值-0.233 mm(95%CI:-1.065,0.598;p=.351),无统计学差异。
关键数值与推荐
- CAL变化均值-0.233 mm(95%CI:-1.065,0.598;p=.351)。
临床怎么用
- 在3-4个月SPT中,PMPR仍是基础;Er:Yag激光、SDD或PDT不作为常规优先推荐。
局限性
- 证据等级较弱。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To systematically review the literature addressing the following focused questions: "What is the efficacy of either (#1) alternative or (#2) additional methods to professional mechanical plaque removal (PMPR) on progression of attachment loss during supportive periodontal therapy (SPT) in periodontitis patients?". METHODS: A systematic search for randomized clinical trials was performed. Change in clinical attachment level (CAL) from baseline was the primary outcome. RESULTS: Routine PMPR performed with either a combination of ultrasonic/hand instruments or Er:Yag laser showed similarly effective in preventing CAL loss. Moreover, a routine SPT regimen based on PMPR led to stability of CAL irrespective of a daily sub-antimicrobial doxycycline dose (SDD). Finally, an adjunctive photodynamic therapy (PDT) did not enhance the magnitude of CAL gain when sites with probing depth ≥4 mm were repeatedly treated. After pooling all data, the results of the meta-analysis showed no statistical differences in CAL change from baseline: mean overall CAL change was -0.233 mm (95% confidence interval: -1.065, 0.598; p = .351). CONCLUSIONS: Weak evidence indicate that in treated periodontitis patients enrolled in a 3-4 month SPT based on PMPR, Er:Yag laser (as alternative), SDD and PDT (as additional) do not produce a greater clinical effect on periodontal conditions compared to PMPR.
引用
- Trombelli L, Farina R, Pollard A, et al. Efficacy of alternative or additional methods to professional mechanical plaque removal during supportive periodontal therapy: A systematic review and meta-analysis. J Clin Periodontol. 2020. PMID: 32060940. doi:10.1111/jcpe.13269
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。