组织水平种植体经机械或改性穿龈颈部表面的3年多中心随机对照概念验证研究
这项多中心随机对照概念验证研究比较了亲水性喷砂酸蚀改性穿龈颈部(mSLA)与机械颈部种植体周围软组织变化。43例受试者随机植入4.1mm直径、1.8mm颈高的种植体,38例完成36个月随访。结果显示两组在改良龈沟出血指数、种植体存留率、成功率及影像学骨水平变化上均无显著差异。
要点
- 改性mSLA穿龈颈部在3年内未显示优于机械颈部的临床或影像学获益
- 36个月时两组无出血位点比例分别为77.6%和78.9%,差异无统计学意义
- 36个月成功率mSLA组86.4%、机械组85.7%,种植体存留率分别为95.5%和100%
核心结论
- 亲水性mSLA改性穿龈颈部组织水平种植体在3年内未较机械颈部种植体产生临床和影像学获益。
研究设计与样本
- 多中心随机对照概念验证研究,43例受试者随机植入4.1mm直径、1.8mm颈高种植体,38例完成36个月随访。
主要发现
- 36个月时mSLA组77.6%、机械组78.9%的种植体无出血位点(mSBI=0;p > .05)。
- 36个月成功率mSLA组86.4%、机械组85.7%(p > .05)。
- 种植体存留率mSLA组95.5%、机械组100%(p > .05)。
- 36个月时影像学骨水平较基线的平均变化mSLA组0.33 ± 0.69 mm、机械组0.12 ± 0.3 mm(p > .05)。
临床怎么用
- 对于组织水平种植体,改性穿龈颈部表面未显示额外临床优势,选择机械颈部即可。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Surface modification may yield enhanced soft tissue adhesion to transmucosal titanium implant necks. AIM: To evaluate and compare changes in soft tissues around implants with a modified hydrophilic sandblasted and acid-etched neck (mSLA; test) to those with a machined neck (M; control). MATERIALS AND METHODS: Implants with a diameter of 4.1 mm and a neck height of 1.8 mm were randomly inserted in healed sites with pristine bone of the posterior maxilla or mandible. The modified Sulcus Bleeding Index (mSBI) (primary outcome) was assessed at baseline (BL) and 6, 12 and 36 months. Secondary outcomes included the assessment of pocket probing depth (PPD), mucosal recession (REC) and clinical attachment level (CAL). Standardized radiographs were taken at time of implant placement, at BL and after 12 and 36 months. RESULTS: Of the 43 randomized subjects, 38 (19 test and 19 controls) completed the 36-month follow-up. Implant survival rates amounted to 95.5% (test) and 100% (control) (p > .05). At 36 months, 77.6% of test implants and 78.9% of control implants were without any bleeding sites (mSBI = 0; p > .05). The 36-month success rate was 86.4% in the test and 85.7% in the control group, respectively (p > .05). At 36 months, the mean radiographic bone level change from BL was 0.33 ± 0.69 mm at test implants and 0.12 ± 0.3 mm at control implants (p > .05). CONCLUSION: Tissue level implants with a hydrophilic mSLA transmucosal neck failed to yield clinical and radiographic benefits compared with implants with a machined neck up to 3 years.
引用
- Salvi GE, Moëne R, Wallkamm B, et al. Clinical and radiographic changes at tissue level implants with either a machined or a modified transmucosal neck surface: A 3-year multicentre randomized controlled proof-of-concept study. J Clin Periodontol. 2020. PMID: 31912523. doi:10.1111/jcpe.13249
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。