氧化锆种植体单冠或固定桥修复的5年前瞻性队列结果
本前瞻性队列研究在两家中心纳入60例患者共71枚一段式氧化锆种植体,行单冠或三单位固定桥修复并随访5年。5年生存率为98.4%(95%CI 91.6, 99.9),种植体植入至5年随访的平均边缘骨丧失为0.7±0.6 mm,加载后边缘骨水平无进一步统计学显著变化(p = .458)。结论认为该种植体中期修复单冠或固定桥安全可靠。
要点
- 一段式氧化锆种植体5年生存率98.4%(95%CI 91.6, 99.9)。
- 植入至5年平均边缘骨丧失0.7±0.6 mm,加载后无显著变化(p = .458)。
- 5年随访时黏膜边缘水平保持稳定。
核心结论
- 一段式氧化锆种植体修复单冠或固定桥5年后生存率高、边缘骨与黏膜边缘稳定,中期可视为安全可靠。
研究设计与样本
- 前瞻性队列研究,两家研究中心,纳入60例患者共71枚一段式氧化锆种植体,修复单冠或三单位固定桥并随访5年。
- 下颌愈合至少2个月、上颌至少4个月后行最终全瓷单冠或三单位固定桥粘接。
主要发现
- 1枚种植体未获得 adequate 骨结合,于植入后5周取出。
- 5年生存率为98.4%(95%CI 91.6, 99.9)。
- 种植体植入至5年随访的平均总体边缘骨丧失为0.7±0.6 mm。
- 加载前平均边缘骨丧失为0.7 mm,此后边缘骨水平无进一步统计学显著变化(p = .458)。
- 5年功能后黏膜边缘水平保持稳定。
临床怎么用
- 对于单冠或三单位固定桥修复,一段式氧化锆种植体可作为中期可行的选择。
- 需关注加载前边缘骨改建,加载后边缘骨水平趋于稳定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the clinical and radiological outcomes of one-piece zirconia implants restored with single crowns (SCs) or fixed dental prostheses (FDPs) over an observation period of 5 years in function. MATERIALS AND METHODS: In a prospective cohort investigation with two investigational centers, one-piece zirconia implants were placed in anterior and posterior sites. After a healing period of at least 2 months in the mandible and 4 months in the maxilla with immediate provisional reconstructions, the final all-ceramic SCs or three-unit FDPs were cemented. Patients were followed for 5 years. Clinical parameters and radiological measurements of the implants and the neighboring teeth were assessed. For the statistical analysis, linear mixed models were applied. RESULTS: A total of 71 implants were placed in 60 patients. Sixty-three implants in 53 patients could be evaluated at the 5-year follow-up. Six patients with a total of seven implants were counted as dropouts. One implant did not achieve adequate osseointegration and had to be removed 5 weeks after implantation. The 5-year survival rate was calculated as 98.4% (95% CI 91.6, 99.9). The mean overall marginal bone loss from implant placement to the 5-year follow-up was 0.7 ± 0.6 mm. After an initial mean marginal loss before loading the implants (0.7 mm), no further statistically significant change in marginal bone level (p = .458) could be observed. CONCLUSION: The investigated one-piece zirconia implant showed a high survival rate, very stable marginal bone, and mucosal margin levels after 5 years in function. Therefore, it can be considered safe and reliable for the reconstruction of implant-supported SCs or FDPs over a mid-term period.
引用
- Balmer M, Spies BC, Kohal RJ, et al. Zirconia implants restored with single crowns or fixed dental prostheses: 5-year results of a prospective cohort investigation. Clin Oral Implants Res. 2020. PMID: 31981374. doi:10.1111/clr.13581
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。