文献速递牙体牙髓病

优化扭矩反转运动对根管预备扭矩和力的影响

Effect of Optimum Torque Reverse Motion on Torque and Force Generation during Root Canal Instrumentation with Crown-down and Single-length Techniques.
PubMed 文献 · J Endod · 2019-12-27

结果显示OTR在冠向下预备阶段和单长度技术的根尖预备阶段降低最大扭矩和向上力。

要点

  • OTR在冠向下预备阶段降低最大扭矩和向上力。
  • 单长度技术根尖预备时OTR降低顺/逆时针最大扭矩。
  • OTR在两种技术下均降低根尖最大向上力。

核心结论

  • 在本实验条件下,OTR运动在冠向下技术的冠向下预备阶段和单长度技术的根尖预备阶段降低扭矩和旋入力。

研究设计与样本

  • 使用扭矩/力分析装置(300 rpm,上下速度10 mm/min)和EndoWave器械预备至#25/0.06锥度。

主要发现

  • 冠向下预备阶段(#35/0.08、#30/0.06、#25/0.06、#20/0.06),OTR的最大扭矩和向上力低于连续旋转。
  • 单长度技术根尖预备阶段(#25/0.06),OTR的最大顺/逆时针扭矩显著低于连续旋转(P < .05)。
  • 两种技术下OTR的最大向上力均显著低于连续旋转(P < .05)。

临床怎么用

  • 临床使用OTR运动可能在冠向下预备和单长度根尖预备时降低扭矩和旋入力。

局限性

  • 研究使用树脂模拟直根管,非真实牙本质根管。
  • 体外实验条件可能不完全反映临床情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Optimum torque reverse (OTR) motion is a torque-sensitive reciprocal motion in which the motor rotates in alternating 90° counterclockwise and 180° clockwise rotation when the torque exceeds a predetermined value. This study aimed to examine whether OTR motion contributes to torque and force reduction during nickel-titanium rotary instrumentation with the crown-down or single-length technique. METHODS: Twenty-eight simulated straight canals in resin blocks were divided into 2 groups according to the type of motion (OTR or continuous rotation). The groups were further subdivided according to the preparation technique (crown-down or single-length technique, n = 7 each). Automated root canal instrumentation was performed with a torque/force analyzing device (300 rpm, up-and-down speed of 10 mm/min) and EndoWave instruments (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) to size #25/0.06 taper. Maximum torque and apical force were recorded and analyzed with analysis of variance and the Bonferroni test. RESULTS: During the crown-down preparation phase (#35/0.08, #30/0.06, #25/0.06, and #20/0.06), OTR motion developed lower maximum torque and upward force (representing the screw-in force) than continuous rotation. During the apical preparation phase (#25/0.06), OTR motion generated significantly lower maximum clockwise and counterclockwise torque (P < .05) when the single-length technique was used and significantly lower maximum upward force regardless of the preparation technique (P < .05) compared with continuous rotation. CONCLUSIONS: Under the present experimental conditions, OTR motion reduced both torque and screw-in force during the crown-down preparation phase of the crown-down technique and during the apical preparation phase of the single-length technique.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Kimura S, Ebihara A, Maki K, et al. Effect of Optimum Torque Reverse Motion on Torque and Force Generation during Root Canal Instrumentation with Crown-down and Single-length Techniques. J Endod. 2019. PMID: 31889584. doi:10.1016/j.joen.2019.11.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。