文献速递牙体牙髓病

不同开髓洞型设计与XP-endo Finisher对根管内粪肠球菌减少的影响

The Effects of Different Endodontic Access Cavity Design and Using XP-endo Finisher on the Reduction of Enterococcus faecalis in the Root Canal System.
PubMed 文献 · J Endod · 2020-01-21

本研究采用80颗下颌第一磨牙,比较传统开髓洞型(TEC)与缩小开髓洞型(CEC)在配合或不配合XP-endo Finisher(XPF)时对根管内粪肠球菌的清除效果。结果显示所有器械处理后细菌均显著减少,CEC-Reciproc-XPF组细菌减少百分比最低(82.8%);TEC与CEC间及是否使用XPF间无显著差异。

要点

  • 传统与缩小开髓洞型对粪肠球菌的减少效果相似。
  • XP-endo Finisher的使用未显著改变细菌减少水平。
  • CEC-Reciproc-XPF组细菌减少百分比最低为82.8%。

核心结论

  • TEC与CEC开髓洞型对根管内粪肠球菌的减少程度相似。
  • 使用XP-endo Finisher未在各组间显示出显著差异。

研究设计与样本

  • 选用80颗下颌第一磨牙随机分为TEC和CEC两组(n=40/组)。
  • 80个近中颊根管感染粪肠球菌4周后,每组再分4个亚组(10牙/组):Reciproc或ProTaper Next联合或不联合XPF。
  • 器械处理前后用无菌纸尖取样,以CFU/mL计数细菌减少量,采用三因素重复测量方差分析及Bonferroni校正(α<.05)。

主要发现

  • 所有不同洞型设计的样本在器械处理后粪肠球菌数量均显著减少。
  • 细菌减少百分比最低值出现在CEC-Reciproc-XPF组(82.8%)。

关键数值与推荐

  • 细菌减少百分比最低值为82.8%(CEC-Reciproc-XPF组)。
  • 统计学显著性水平设定为α<.05。

临床怎么用

  • 缩小开髓洞型与传统开髓洞型在粪肠球菌清除上效果相当,临床可按需选择。
  • XP-endo Finisher作为辅助冲洗装置,对本研究中的细菌减少未显示额外显著获益。

局限性

  • 原文未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to evaluate the effect of using the XP-endo Finisher (XPF; FKG Dentaire, La Chaux de Fonds, Switzerland) in teeth that have a traditional access cavity (TEC) and a contracted access cavity (CEC) design on the amount of decrease in the number of Enterococcus faecalis bacteria within the root canal system. METHODS: Eighty mandibular first molar teeth were selected and randomly divided into 2 groups: TEC and CEC (n = 40/group). After access cavity preparation in the 2 groups, 80 mesiobuccal root canals were contaminated with Enterococcus faecalis for 4 weeks. After the first sampling (S1), in order to perform root canal instrumentation, the TEC and CEC groups were further divided into 4 subgroups (10 teeth/group): Reciproc (VDW GmbH, Munich, Germany) and ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland) with or without XPF. Bacterial sampling from the root canals was performed with sterile paper points before (S1) and after (S2) instrumentation to determine the bacterial load. The bacterial reduction was counted as colony-forming units/mL and analyzed statistically by 3-factor repeated measures analysis of variance. Multiple comparisons of the main factor effect were performed using the Bonferroni correction (α < .05), all at 5% significance. RESULTS: The number of E. faecalis bacteria in all the samples with different cavity designs were significantly reduced after instrumentation. The lowest value of bacterial decrease percentage was observed in the CEC-Reciproc-XPF (82.8%) group. CONCLUSIONS: The bacterial reduction counts of E. faecalis were a similar level in the TEC and CEC cavities, and the use of XPF did not show significant differences between groups.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Tüfenkçi P, Yılmaz K. The Effects of Different Endodontic Access Cavity Design and Using XP-endo Finisher on the Reduction of Enterococcus faecalis in the Root Canal System. J Endod. 2020. PMID: 31980201. doi:10.1016/j.joen.2019.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。