文献速递口腔修复与种植

三种新型种植覆盖义齿附着体在不同种植体角度下循环脱位时固位力变化的体外研究

In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations.
PubMed 文献 · Clin Oral Implants Res · 2020-01-09

本体外研究比较三种新型非夹板式附着体在模拟下颌双种植体覆盖义齿、不同种植体间角度(0°、20°、40°、60°)下经10,000次循环脱位后的固位力变化。结果显示所有系统均表现出可用于临床的固位力,即使种植体角度极大;补偿种植体间角度的特定基台在高轴向偏差情况下能更长时间维持固位。

要点

  • 所有附着体在10,000次循环后仍保持有临床成功潜力的固位力,包括极度倾斜种植体情况。
  • N系统在1,000次循环前固位力增加,至10,000次回到初始水平,全程无显著损失。
  • L系统在40°及以上角度导致较低固位力;C系统仅在10,000次循环(所有角度)或5,000次循环(0° vs 60°)时出现显著损失。

核心结论

  • 所有测试的附着体系统均显示出有希望成功用于种植覆盖义齿的固位力,即使在种植体极度倾斜的情况下也是如此。
  • 补偿种植体间角度的特定基台在高轴向偏差情况下能更长时间维持固位。

研究设计与样本

  • 体外研究,模拟下颌双种植体覆盖义齿情况,种植体间角度为0°、20°、40°和60°。
  • 测试三种附着体系统:N(直或15°倾斜的球帽)、L(仅直球帽)、C(直或个体化倾斜的球帽)。
  • 所有模型进行湿测试,在万能试验机上经受10,000次插入-移除循环,计算第10、100、1,000、5,000和10,000次循环的平均固位力。
  • 采用多重混合效应线性回归模型进行统计分析(α < 0.05)。

主要发现

  • N系统固位力增加至1,000次循环,随后在10,000次循环时降至初始固位力,整个实验期间无显著损失。
  • 统计模型显示种植体角度对固位力无影响,除了60°在10,000次循环后(p < .05)。
  • L系统在100次循环出现早期峰值,在5,000次循环前无显著固位力损失;40°或更高角度导致较低固位力(0° vs 40° 第5,000次循环:p < .05;0° vs 60° 第100次循环:p < .05,≥第1,000次循环:p < .001)。
  • C系统仅在10,000次循环(所有角度:p < .001)或5,000次循环(0° vs 60°:p < .05)时显示固位力显著损失。

关键数值与推荐

  • N系统:10,000次循环后无显著固位力损失,60°角度在10,000次循环后对固位力有影响(p < .05)。
  • L系统:40°或更高角度导致较低固位力(0° vs 40° 第5,000次循环:p < .05;0° vs 60° 第100次循环:p < .05,≥第1,000次循环:p < .001)。
  • C系统:10,000次循环所有角度固位力显著损失(p < .001);5,000次循环0° vs 60°固位力显著损失(p < .05)。

临床怎么用

  • 对于种植体间角度大的病例,可选择能补偿角度的特定基台以更长时间维持固位。
  • 所有三种附着体系统在体外循环测试中均表现出可用于临床的固位力,即使种植体角度极大。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This in vitro study aimed to compare changes in retentive force due to cyclic dislodging of three novel un-splinted attachments. MATERIALS AND METHODS: Experimental models simulating a mandibular two-implant overdenture situation, with implants positioned with various interimplant discrepancies (0°, 20°, 40°, and 60°) were fabricated. Three attachment systems were tested, "N": a straight or 15°-angulated stud; "L": a sole straight stud; and "C": a straight or individually angulated stud. All models underwent wet testing and were subjected to 10,000 insertion-removal cycles in a universal testing machine. The mean retentive forces were calculated for cycles 10, 100, 1,000, 5,000, and 10,000. Multiple mixed-effects linear regression models were applied for statistical analyses (⍺ < 0.05). RESULTS: "N" demonstrated an increasing retention until 1,000 cycles, which subsequently diminished back to its initial retention at 10,000 cycles, showing no significant loss during the entire experiment. Statistical models demonstrated no effect of implant angulation on retention, except for 60° after 10,000 cycles (p < .05). "L" showed an early peak at 100 cycles and did not significantly lose retentive force before 5,000 cycles. Angulations of 40° or higher were shown to lead to lower retentive forces (0° vs. 40° cycle 5,000: p < .05; 0° vs. 60° cycle 100: p < .05, ≥cycle 1,000: p < .001). "C" showed stable retentive forces with no significant loss only at 10,000 cycles (all angles: p < .001) or 5,000 cycles (0° vs. 60°: p < .05). CONCLUSIONS: All systems showed retentive forces promising successful clinical use in implant overdentures, even in situations with extremely angulated implants. Specific abutments compensating interimplant angulation maintain retention longer in situations with high axe divergencies.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Maniewicz S, Badoud I, Herrmann FR, et al. In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations. Clin Oral Implants Res. 2020. PMID: 31876004. doi:10.1111/clr.13567

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。