术前小视野CBCT预测术中颊侧皮质骨的准确性
本研究回顾性分析2016至2018年两家牙髓诊所的125例显微根尖手术病例,比较术前小视野CBCT与术中记录的颊侧皮质骨状态。结果显示CBCT预测颊侧骨有无的阳性预测值和阴性预测值均较高,准确率超过80%,且不受重建层厚、观察平面或评估者影响。
要点
- 术前小视野CBCT能准确预测术中颊侧皮质骨状态,尤其完整颊侧骨板和开窗。
- 预测颊侧骨存在的阳性预测值为86.5%,预测骨缺损的阴性预测值达89%至96%。
- CBCT预测准确性不受重建层厚、观察平面或评估者影响。
核心结论
- 术前小视野CBCT对术中颊侧皮质骨状态具有高度区分能力,预测准确。
- 尤其对完整颊侧骨板和开窗的预测准确性高。
研究设计与样本
- 回顾性研究,纳入2016至2018年两家牙髓诊所的125例显微根尖手术病例。
- 由两名校准的独立评估者在两种重建层厚的多平面旁矢状面和旁轴面评估术前CBCT。
- 评估结果与电子健康记录中的术中手术发现进行比较。
主要发现
- 术中记录完整颊侧骨板患病率为49%,骨开裂为7%,开窗为44%。
- 完整颊侧骨板的阳性预测值为86.5%;骨开裂的阴性预测值为96%;开窗的阴性预测值为89%。
- 敏感性和特异性范围为80%至90%,所有变量的预测准确率均超过80%。
关键数值与推荐
- 预测准确率不受重建观察层厚、观察平面或评估者的显著影响。
- 统计学显著性设定为P < .05。
临床怎么用
- 术前小视野CBCT可用于显微根尖手术前评估颊侧皮质骨状态,辅助预后判断和手术规划。
- 尤其可借助高阴性预测值排除骨开裂和开窗,借助高阳性预测值确认完整颊侧骨板。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Limited field of view cone-beam computed tomography (LFOV CBCT) is the primary imaging modality recommended for treatment planning before endodontic microsurgery (EMS). Persistent apical periodontitis, often treated with EMS, results in changes in the buccal cortical plate that may detrimentally impact prognosis. The accuracy of a preoperative LFOV CBCT to predict intraoperative findings is unclear. METHODS: Electronic health records (EHRs) of EMS performed at 2 endodontic offices between 2016 and 2018 were reviewed retrospectively. EHR data extracted were documented for surgical findings of intact buccal cortical plate, fenestration, dehiscence, and height of remaining buccal collar of bone. Two calibrated, independent reviewers evaluated presurgical LFOV CBCTs in the multiplanar paraxial and parasagittal planes at 2 different reconstructed viewing plane thicknesses. Reviewer findings were compared with EHR documentation. Data were analyzed by using χ2, logistic regression, and multivariable analysis. Significance was set at P < .05. RESULTS: Within the 125 EMS cases included in the study, the EHR prevalence of intact buccal cortical plate was 49%, dehiscence 7%, and fenestration 44%. The imaging predictive value, whether it was negative (NPV) or positive (PPV), was higher when predicting presence of buccal bone (PPV of intact buccal cortical plate = 86.5%; NPV of dehiscence = 96%; NPV of fenestration = 89%). Sensitivity and specificity ranged from 80%-90%. Accuracy in prediction was high for all variables, exceeding 80%. Accuracy was not significantly influenced by reconstructed viewing slice thickness, viewing plane, or reviewer. CONCLUSION: Preoperative LFOV CBCT was highly discriminatory and accurately predicted intraoperative buccal cortical bone status, especially intact buccal cortical plate and fenestration.
引用
- Mayo CV, Replogle KJ, Marshall JG, et al. Accuracy of Presurgical Limited Field of View Cone-beam Computed Tomography in Predicting Intraoperative Buccal Cortical Bone. J Endod. 2019. PMID: 31839413. doi:10.1016/j.joen.2019.10.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。