文献速递牙体牙髓病

TRUShape与XP-endo Shaper对中度弯曲根管成形能力的微CT对比研究

TRUShape Versus XP-endo Shaper: A Micro-computed Tomographic Assessment and Comparative Study of the Shaping Ability-An In Vitro Study.
PubMed 文献 · J Endod · 2019-12-13

结果显示两组在成形能力、未处理根管壁面积、根管体积、根管偏移度和中心定位能力上均无统计学显著差异(P > .05)。结论为两种器械对中度弯曲根管的预备效果相当。

要点

  • XP单锉与TRUShape对中度弯曲根管的成形效果相当。
  • 两组在未处理根管壁比例、根管偏移和中心定位上无显著差异(P > .05)。
  • 两种器械均能较好地维持根管原始解剖形态。

核心结论

  • 使用XP单锉和TRUShape系统预备中度弯曲根管的效果相当。
  • 两种器械均维持了根管原始解剖形态,未处理根管壁百分比、中心定位能力和根尖偏移均相似。

研究设计与样本

  • 预备前后使用SkyScan 1275微CT扫描,名义分辨率<4 μm。
  • 前磨牙和冲洗液在预备前及预备过程中维持37°。
  • 组1使用XP-endo Shaper,组2使用TRUShape。
  • 使用Mann-Whitney-Wilcoxon检验比较均数和中位数,显著性水平设为5%(P < .05)。

主要发现

  • 两组在成形能力、未处理根管壁面积、根管偏移度和中心定位能力上均无统计学显著差异(P > .05)。

临床怎么用

  • 对于中度弯曲根管,XP-endo Shaper单锉系统和TRUShape多锉系统均可作为预备选择,两者成形效果相当。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to evaluate and compare the shaping ability of XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) and TRUShape (TS; Dentsply/Tulsa Dental Specialties, Tulsa, OK) during the preparation of moderated curved root canals using micro-computed tomographic imaging. METHODS: Twenty human maxillary premolars with 2 roots were randomly separated into 2 groups of 10 teeth, which were scanned before and after root canal preparation using the SkyScan 1275 X-ray microtomograph (Bruker micro-CT, Kontich, Belgium) at a nominal resolution of <4 μm. Premolars and irrigant were maintained at 37° before and during preparation; group 1 was treated using XP and group 2 with TS. After preparation, researchers measured the amount of dentin removed, untreated superficies of canal walls, root canal volume, degree of canal transportation, and centering ability. Values of central tendency and dispersion were calculated using Statgraphics Centurion XV software (StatPoint Technologies, Inc, Warrenton, VA); means and median were compared using the Mann-Whitney-Wilcoxon test. The level of significance was set at 5% (P < .05). RESULTS: No significant statistical differences were observed between the 2 groups in shaping ability, untreated superficies of canal walls, degree of canal transportation, and centering ability (P > .05). CONCLUSIONS: Instrumentation of moderately curved root canals using the XP single file and the TS file system were equally effective. XP and TS maintained the original anatomy of the root canals and showed a similar percentage of untreated canal walls, centered ability, and minimal apical transportation.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Perez Morales MLN, González Sánchez JA, Olivieri Fernández JG, et al. TRUShape Versus XP-endo Shaper: A Micro-computed Tomographic Assessment and Comparative Study of the Shaping Ability-An In Vitro Study. J Endod. 2019. PMID: 31839412. doi:10.1016/j.joen.2019.10.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。