文献速递口腔修复与种植

应用共振频率分析评估不同表面处理对种植体稳定性的影响

Use of resonance frequency analysis to evaluate the effects of surface properties on the stability of different implants.
PubMed 文献 · Clin Oral Implants Res · 2019-12-20

结果显示碱改性种植体在植入后即刻ISQ显著高于喷砂组,但2周和6周时两组ISQ快速下降且相似(p > .05),3个月时两组ISQ相同(p > .05)。结论认为碱改性表面种植体在植入后各时间点均更稳定,但高初始稳定性的生物活性种植体在术后2周和6周ISQ下降幅度更大,12周时两组临床结果相似。

要点

  • 碱改性表面种植体植入后即刻ISQ显著高于喷砂表面种植体。
  • 术后2周和6周两组ISQ快速下降且差异无统计学意义(p > .05)。
  • 术后3个月两组ISQ相同,临床结果相似(p > .05)。

核心结论

  • 碱改性表面种植体在植入后各时间点均比喷砂表面种植体更稳定。
  • 高初始稳定性的生物活性种植体在术后2周和6周ISQ下降幅度大于喷砂表面种植体。
  • 两种种植体在术后12周临床结果相似。

研究设计与样本

  • 共使用50枚直径和长度相同的种植体,碱改性(生物活性)与喷砂表面种植体随机 placed 于左右半颌。
  • 采用共振频率分析测量种植体稳定系数(ISQ),时间点为植入后即刻及2、6、12周。

主要发现

  • 碱改性种植体植入后即刻平均RFA值显著高于喷砂种植体。
  • 2周和6周时两组ISQ快速下降且相似(p > .05)。
  • 3个月时两组ISQ值相同(p > .05)。

关键数值与推荐

  • 碱改性种植体即刻ISQ显著高于喷砂组(具体数值原文未报告)。
  • 2周和6周组间ISQ比较p > .05。
  • 3个月组间ISQ比较p > .05。

临床怎么用

  • 共振频率分析可用于评估种植体初期稳定性及随访稳定性变化。
  • 对于高初始稳定性的生物活性表面种植体,术后早期ISQ下降幅度可能更大,需注意随访监测。

局限性

  • 仅评估下颌磨牙区,结论外推需谨慎。
  • 随访时间仅至术后12周。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We performed a randomized clinical study evaluating the stability of implants with different surfaces (alkali-modified or sandblasted) via resonance frequency analysis (RFA). MATERIALS AND METHODS: Fourteen patients who were bilaterally edentulous in terms of their mandibular molars were enrolled. Implants with alkali-modified (bioactive) and sandblasted surfaces were randomly placed in either hemi-arch; the 50 implants used were identical in terms of diameter and length. RFA was used to measure the implant stability quotient (ISQ) immediately after placement (to assess primary stability) and 2, 6, and 12 weeks later. RESULTS: The average RFA value for alkali-modified implants was significantly higher than that for sandblasted implants immediately after implantation, but the ISQs fell rapidly and were similar in the two groups at 2 and 6 weeks (p > .05); ISQ values were the same in the two groups at 3 months (p > .05). CONCLUSIONS: Implants with alkali-modified surfaces were more stable than implants with sandblasted surfaces at all times after placement. The ISQs of bioactive implants exhibiting high-level primary stability fell to greater extents than did those of implants with sandblasted surfaces at 2 and 6 weeks postoperatively; both types of implant yielded similar clinical results at 12 weeks postoperatively.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Gursoytrak B, Ataoglu H. Use of resonance frequency analysis to evaluate the effects of surface properties on the stability of different implants. Clin Oral Implants Res. 2019. PMID: 31758589. doi:10.1111/clr.13560

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。