文献速递口腔修复与种植口腔颌面外科

兔股骨模型同期植入种植体后10周无细胞矿化同种异体块状骨移植不重塑

Acellular mineralized allogenic block bone graft does not remodel during the 10 weeks following concurrent implant placement in a rabbit femoral model.
PubMed 文献 · Clin Oral Implants Res · 2019-10-10

研究在兔股骨模型中同期植入种植体时比较自体骨与同种异体骨移植的效果。同种异体骨组微CT显示骨体积和骨体积分数较低,组织学未见差异,但同种异体骨无活细胞且最大压缩载荷显著低于自体骨。结论认为同种异体块状骨与种植体同期植入产生的骨质量较自体骨差。

要点

  • 同种异体骨移植后10周仍无细胞,骨陷窝空虚。
  • 同种异体骨组微CT骨体积和骨体积分数低于自体骨组。
  • 同种异体骨组移植骨-骨界面最大压缩载荷显著低于自体骨组。

核心结论

  • 同种异体块状骨与种植体同期植入后10周不重塑,产生的骨质量较自体骨差。

研究设计与样本

  • 兔股骨模型,16只3.5 kg雄性新西兰白兔,每侧股骨近端制备4 mm缺损。
  • 自体骨或同种异体骨块(每组n=16)中央预钻3.2 mm孔,同期植入 machined 3.2×10 mm 喷砂酸蚀钛铝钒(Ti6Al4V)种植体。
  • 对照种植体植入对侧肢体逐级扩至3.2 mm的孔中。
  • 植入后70天进行微CT和钙化组织学分析,或行机械扭矩和推出测试后行脱钙组织学分析。

主要发现

  • 两种骨块均与宿主骨整合。
  • 微CT显示同种异体骨组骨体积(BV)和骨体积/总体积(BV/TV)低于自体骨组,但组织学显示两组BV或BV/TV无差异。
  • 同种异体骨无活细胞,而自体骨有细胞。
  • 两组最大拆除扭矩无差异。
  • 同种异体骨组移植骨-骨界面最大压缩载荷显著低于自体骨组。

临床怎么用

  • 同期植入种植体时,同种异体块状骨可能不如自体骨有利于形成高质量骨结合。

局限性

  • 动物模型(兔股骨)结果外推至人类需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Due to bone loss, endosseous implants often require addition of a bone graft to support adequate primary fixation, bone regeneration, and osseointegration. The aim of this study was to compare effectiveness of autogenic and allogenic bone grafts when used during simultaneous insertion of the implant. MATERIALS AND METHODS: 4-mm-diameter rabbit diaphyseal bone autografts or allografts (n = 16/group) with a 3.2-mm pre-drilled hole in the center were placed into a 4 mm defect in the proximal femur of 3.5 kg male New Zealand White rabbits. Machined 3.2 × 10 mm grit-blasted, acid-etched titanium-aluminum-vanadium (Ti6Al4V) implants were placed. Control implants were placed into progressively drilled 3.2-mm holes in the contralateral limbs. Post-insertion day 70, samples were analyzed by micro-CT and calcified histology, or by mechanical torque and push-out testing followed by decalcified histology. RESULTS: Both grafts were integrated with the native bone. Micro-CT showed less bone volume (BV) and bone volume/total volume (BV/TV) in the allograft group, but histology showed no differences in BV or BV/TV between groups. Allograft lacked living cells, whereas autograft was cellularized. No difference was found in maximum removal torque between groups. Compressive loading at the graft-to-bone interface was significantly lower in allograft compared with autograft groups. CONCLUSIONS: There was less bone in contact with the implant and significantly less maximum compressive load in the allograft group compared with autograft. The allograft remained acellular as demonstrated by empty lacunae. Taken together, block allograft implanted simultaneously with an implant produces a poorer quality bone compared with autograft.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Cohen DJ, Scott KM, Kulkarni AN, et al. Acellular mineralized allogenic block bone graft does not remodel during the 10 weeks following concurrent implant placement in a rabbit femoral model. Clin Oral Implants Res. 2019. PMID: 31545532. doi:10.1111/clr.13544

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。