文献速递口腔修复与种植

化学修饰与中度粗糙钛种植体在悬臂修复下过度咬合负荷的动物实验研究

Excessive occlusal load on chemically modified and moderately rough titanium implants restored with cantilever reconstructions. An experimental study in dogs.
PubMed 文献 · Clin Oral Implants Res · 2019-10-08

本研究在五只犬下颌植入SLA和SLActive种植体,分别给予稳定咬合、过度咬合(悬臂)和无负荷处理,评估临床、影像和 histological 结果。发现过度咬合未导致骨结合丧失或显著临床变化,但SLA过度负荷组种植体周围骨密度显著增加,且技术并发症更多。

要点

  • 过度咬合负荷未导致种植体骨结合丧失或临床参数显著变化。
  • SLA种植体早期过度负荷可促进种植体周围骨密度增加。
  • 过度负荷种植体技术并发症(螺丝松动、基台折断)发生率更高。

核心结论

  • 过度咬合负荷应用于悬臂修复的SLA或SLActive种植体未导致骨结合丧失或临床、影像、组织学显著改变。
  • SLA种植体早期过度负荷可促进种植体周围骨密度增加。
  • 过度负荷种植体显示出更多技术并发症。

研究设计与样本

  • 在五只犬中拔除所有下颌前磨牙,三个月后植入六颗种植体(三颗SLA,三颗SLActive)。
  • 四周后修复:一颗单冠稳定咬合(SC),一颗冠加悬臂过度咬合(OL),一颗无负荷(NL)。

主要发现

  • SLA和SLActive种植体在菌斑指数、牙龈指数、黏膜边缘、附着水平和骨丧失方面结果相似。
  • 所有临床参数在基线和24周之间或不同处理方式间无显著差异(p > .05)。
  • 负荷六个月后,RFA值显著高于种植体植入时,不同处理方式间无显著差异。
  • SLA过度负荷组种植体周围骨密度相对于其他所有组有统计学显著增加(p = .012)。

关键数值与推荐

  • SLA过度负荷组种植体周围骨密度增加具有统计学显著性(p = .012)。
  • 技术并发症:咬合螺丝松动发生率13.3%(SC=3.3%;OL=10%),基台折断发生率23.3%(SC=6.6%;OL=16.6%)。

临床怎么用

  • 过度咬合负荷可能不直接导致种植体骨结合丧失,但需警惕技术并发症风险。
  • 对于SLA种植体,早期过度负荷可能有助于增加种植体周围骨密度,但需谨慎解释。

局限性

  • 研究为动物实验(犬),样本量小(五只犬),结果需谨慎外推至人类。
  • 观察期较短(负荷后六个月),长期影响未评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the outcomes of excessively loaded implants. MATERIAL AND METHODS: In five dogs, all mandibular premolars were extracted. After 3 months, six implants (three SLA® and three SLActive®) were placed (S). After 4 weeks, implants were restored: one single crown with stable occlusal contacts (SC), one crown and a cantilever unit with excessive occlusal contacts (OL), and a non-loaded implant (NL). Bleeding-on-probing (BoP), attachment level (AL), mucosal margin (GM) were assessed. Resonance frequency analysis (RFA) was assessed weekly. Standardized X-rays were taken at S, 4 and 24 weeks. RESULTS: Similar findings were observed for SLA® and SLActive® implants regarding PlI, GI, GM, AL, and BL. No significant differences were detected between baseline and 24-weeks or between treatment modalities for all clinical parameters (p > .05). Six months after loading, RFA values were significantly greater than at implant placement. No significant differences between treatment modalities were found. Linear radiographic measurements yielded similar results between SLA® and SLActive® implants. SLA® OL implants yielded a statistically significant gain on peri-implant bone density over all other groups (p = .012). Radiographic results were confirmed by descriptive histology. Technically, loosened occlusal screws occurred in 13.3% (SC = 3.3%; OL = 10%), while abutment fractures totalized 23.3% (SC = 6.6%; OL = 16.6%). CONCLUSIONS: Excessive occlusal load applied to implants (SLA® or SLActive®) restored with cantilevers did not cause loss of osseointegration or significant changes in their clinical, radiographic, or histologic outcomes. Early excessive occlusal load on SLA® implants promoted a gain in peri-implant bone density. Excessively loaded implants showed more technical complications.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Lima LA, Bosshardt DD, Chambrone L, et al. Excessive occlusal load on chemically modified and moderately rough titanium implants restored with cantilever reconstructions. An experimental study in dogs. Clin Oral Implants Res. 2019. PMID: 31529643. doi:10.1111/clr.13539

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。