骨环技术同期种植是否使用胶原膜的Micro-CT分析:临床前体内研究
该临床前犬模型研究评估胶原膜覆盖对骨环技术同期植入种植体周围骨形成的影响。下颌标准化垂直牙槽骨缺损中同期植入种植体,一侧覆盖胶原膜(M组),对侧不覆盖(NM组),愈合3和6个月后行Micro-CT分析。结果显示膜应用对骨体积无显著负面影响,但对骨-种植体接触(BIC)有显著负面影响(p = .04);愈合帽缺失及种植体暴露也显著损害骨体积和BIC。
要点
- 胶原膜覆盖对骨体积无显著负面影响,但显著降低骨-种植体接触(p = .04)。
- 愈合帽缺失显著损害骨体积(p = .04)和骨-种植体接触(p = .02)。
- 愈合帽丢失及口腔暴露显著降低种植体肩台下2 mm内骨体积(p < .001)和骨密度(p < .05)。
核心结论
- 在本研究局限性内,骨环技术同期种植时应用胶原膜未显示获益。
- 软组织愈合破坏被确定为骨体积和骨-种植体接触下降的风险因素。
研究设计与样本
- 临床前体内研究,在犬下颌标准化垂直牙槽骨缺损中行骨环技术同期植入种植体。
- 下颌一侧覆盖胶原膜(M组),对侧不覆盖(NM组),愈合3和6个月后行Micro-CT分析。
主要发现
- 非参数分析显示膜对骨体积(BV)无显著负面影响,但对骨-种植体接触(BIC)有显著负面影响(p = .04)。
- 愈合帽缺失损害BV(p = .04)和BIC(p = .02)。
- 愈合帽丢失及口腔暴露显著负面影响种植体肩台下2 mm内BV(p < .001)和骨密度(p < .05)。
- 种植体暴露与愈合时间对BV(p = .01)和BIC(p = .01)均有负交互效应。
临床怎么用
- 骨环技术同期种植时不应常规期待胶原膜带来额外获益。
- 应重点保障软组织愈合和愈合帽稳定,避免种植体早期暴露。
局限性
- 研究为临床前犬模型,结论外推至临床需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To assess the impact of collagen membrane application on bone formation surrounding implants placed simultaneously with the bone ring technique. MATERIAL AND METHODS: Dental implants were inserted simultaneously with the bone ring technique in standardized, vertical alveolar bony defects in the mandible of dogs. On one side of the mandible, the augmented sites were covered with a collagen membrane (M-Group). On the contralateral side, no membranes were used (NM-Group). Implants were left to heal with osseointegration for three and six months. The harvested samples were analyzed by means of micro-CT. RESULTS: A nonparametric analysis of data revealed that the membranes were not a significant negative factor for bone volume (BV), but for bone-to-implant contact (BIC, p = .04). Absence of healing caps impaired BV (p = .04) and BIC (p = .02) as well. Furthermore, loss of healing caps and exposure to the oral environment significantly and negatively affected BV (p < .001) and bone mineral density (p < .05) within 2 mm below the implant shoulder. Implant exposure and healing time had a negative interaction effect on both BV (p = .01) and BIC (p = .01). CONCLUSIONS: Within its limitations, the present study revealed no benefit of membrane application to implant placement simultaneous with the bone ring technique. Disruption of soft tissue healing was identified as a risk factor for decrease in BV and BIC.
引用
- Nakahara K, Haga-Tsujimura M, Igarashi K, et al. Single-staged implant placement using the bone ring technique with and without membrane placement: Micro-CT analysis in a preclinical in vivo study. Clin Oral Implants Res. 2019. PMID: 31541500. doi:10.1111/clr.13543
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。