文献速递口腔修复与种植牙周病

前牙位点满足种植体植入的近远中空间与颊舌向牙槽宽度的频率

Frequency of adequate mesiodistal space and faciolingual alveolar width for implant placement at anterior tooth positions.
PubMed 文献 · J Am Dent Assoc · 2019-01-01

该研究由一名检查者分析205例锥形束CT图像,记录前牙各区近远中空间(MS)和颊舌向牙槽宽度(FAW)是否满足种植体植入要求,并与标准化种植体直径比较。结果显示下颌切牙位点常缺乏有利的近远中空间,上颌侧切牙及下颌切牙位点有相当比例在采用常规窄径种植体时存在种植体周围骨厚度不良的风险。

要点

  • 下颌切牙位点常难以满足常规窄径种植体的近远中空间要求。
  • 上颌侧切牙与下颌切牙位点用常规窄径种植体时骨厚度不良风险较高。
  • 许多单颗下颌切牙或上颌侧切牙缺失者可考虑小直径种植体或非种植修复。

核心结论

  • 在该受评估人群中,下颌切牙位点常缺乏容纳常规窄径种植体的有利近远中空间。
  • 相当比例的下颌切牙和上颌侧切牙位点在采用常规窄径种植体时可能面临种植体周围骨厚度不良的风险。

研究设计与样本

  • 由一名检查者分析205例锥形束CT图像,记录前牙位点可用于种植体植入的MS和FAW。
  • 将测量值与标准化种植体直径比较,评估预期种植体至牙齿距离及种植体周围骨厚度。

主要发现

  • 上颌侧切牙位点中,左侧22%、右侧27%的位点种植体平台与相邻牙之间小于2毫米。
  • 下颌切牙位点中,种植体至牙齿距离小于2毫米者占79%至97%,小于1.5毫米者占35%至76%。
  • 超过半数上颌切牙位点及78%至95%下颌切牙位点的FAW在种植体直径之外小于4毫米。

临床怎么用

  • 对许多单颗下颌切牙或上颌侧切牙缺失患者,可考虑小直径种植体或非种植的牙齿替代方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prior studies have defined minimum mesiodistal space (MS) and faciolingual alveolar width (FAW) requirements for dental implant sites, and failure to observe these constraints may adversely impact peri-implant health and esthetics. However, to the authors' knowledge, no previous reports have established frequencies at which anterior tooth positions present favorable MS and FAW for implant accommodation. METHODS: A single examiner analyzed 205 cone-beam computed tomographic images, recording MS and FAW available for implant placement at anterior tooth positions. The examiner compared measurements with standardized implant diameters to assess anticipated implant-to-tooth distances and peri-implant bone thicknesses. RESULTS: In the esthetic zone, lateral incisor sites most frequently failed to present favorable MS. At maxillary lateral incisor positions, 22% (left) and 27% (right) of sites offered less than 2 millimeters between the proposed implant platform and the adjacent teeth. In mandibular incisor positions, implant-to-tooth distance was less than 2 mm at 79% through 97% of sites and less than 1.5 mm at 35% through 76% of sites. Over one-half of maxillary incisor sites and 78% through 95% of mandibular incisor sites exhibited FAW of less than 4 mm beyond implant diameter. CONCLUSIONS: In the population evaluated, mandibular incisor positions frequently presented unfavorable MS to accommodate conventional narrow-diameter implants. In addition, considerable proportions of mandibular incisor and maxillary lateral incisor sites may be at risk of developing unfavorable peri-implant bone thickness when conventional narrow-diameter implants are used. PRACTICAL IMPLICATIONS: Practitioners should consider small-diameter implants and nonimplant tooth replacement methods for many patients missing single mandibular incisors or maxillary lateral incisors.

来源:J Am Dent Assoc,查看原文。版权归原作者所有。

引用

  1. Wilson JP, Johnson TM. Frequency of adequate mesiodistal space and faciolingual alveolar width for implant placement at anterior tooth positions. J Am Dent Assoc. 2019. PMID: 31439205. doi:10.1016/j.adaj.2019.05.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。