文献速递牙体牙髓病

水平连续切片法评估牙本质消毒效果的共聚焦显微镜研究

A Horizontal Sequential Cutting Method to Estimate the Effectiveness of Dentin Disinfection by Using Confocal Laser Scanning Microscopy.
PubMed 文献 · J Endod · 2019-07-31

本研究开发水平连续切片技术,用共聚焦激光扫描显微镜观察感染牙本质内细菌活性。将人类单根牙本质块感染粪肠球菌28天后,分别用2%次氯酸钠处理2或20分钟,温度设为20、37、45°C。结果显示处理时间影响次氯酸钠渗透深度,温度无显著影响,且该方法与染料漂白试验结果一致。

要点

  • 水平连续切片法无需脱钙即可保留牙本质小管内细菌三维分布与活性信息。
  • 次氯酸钠处理时间影响其渗透深度,温度对渗透无显著影响。
  • 共聚焦显微镜分析结果与染料漂白试验一致,验证了方法可靠性。

核心结论

  • 水平连续切片法可连续切片并对每个部分成像,便于评估牙本质消毒效果。

研究设计与样本

  • 研究使用新鲜拔除的人类单根牙制备圆柱形牙本质块,经5%次氯酸钠和17%EDTA各处理5分钟后感染粪肠球菌28天。
  • 样本暴露于2%次氯酸钠2或20分钟,温度分别为20°C、37°C、45°C,随后染色、冷冻包埋并沿牙本质小管方向切片10μm。

主要发现

  • 处理时间影响次氯酸钠向牙本质小管的渗透,温度无显著影响。
  • 共聚焦激光扫描显微镜分析与染料漂白试验结果一致。

关键数值与推荐

  • 2%次氯酸钠处理2分钟或20分钟,温度20°C、37°C、45°C。
  • 切片厚度10μm,感染时间28天。

临床怎么用

  • 该技术可用于体外评估牙本质消毒剂渗透效果,指导根管冲洗方案优化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study aimed to develop a technique to create sequential slices, allowing the fluorescent visualization of bacterial viability in all parts of an infected dentin. METHODS: Cylindrical dentin blocks were prepared from freshly extracted human teeth with a single-rooted canal. Each block was immersed in 5% sodium hypochlorite (NaOCl) and 17% EDTA for 5 minutes before being infected with Enterococcus faecalis. The bacteria were allowed to develop inside dentin specimens for 28 days under anaerobic conditions. The specimens were exposed in 2% NaOCl for either 2 minutes or 20 minutes at 20°C, 37°C, and 45°C, respectively. After staining with calcein AM (Thermo Fisher Scientific, Waltham, MA) and propidium iodide, the samples were cryoembedded, mounted on an adhesive film, and sectioned at a thickness of 10 μm along the running of the dentinal tubules. Stacks of fluorescent images were collected in the z dimension using confocal laser scanning microscopy, and the maximum affected distance from a root canal was measured from the 3-dimensional reconstructed image. The reliability of this technique was verified by comparison with a dye bleaching test. RESULTS: Horizontal sequential sections preserving 3-dimensional bacterial distribution and their viabilities could be made without decalcification. The treatment time contributed to the penetration of NaOCl into dentinal tubules, whereas temperature did not significantly affect the penetration. The judgment by confocal laser scanning microscopic analysis was consistent with that of a dye bleaching test. CONCLUSIONS: The horizontal sectioning method has the advantage of creating sequential sections, allowing information to be imaged at every portion.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Hasegawa T, Takenaka S, Wakamatsu R, et al. A Horizontal Sequential Cutting Method to Estimate the Effectiveness of Dentin Disinfection by Using Confocal Laser Scanning Microscopy. J Endod. 2019. PMID: 31376921. doi:10.1016/j.joen.2019.06.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。