文献速递牙体牙髓病

新型硅酸钙基封闭剂Bio-C Sealer理化性能评价

Evaluation of Physicochemical Properties of a New Calcium Silicate-based Sealer, Bio-C Sealer.
PubMed 文献 · J Endod · 2019-08-22

该体外研究依据ISO 6876标准,比较Bio-C Sealer、TotalFill BC Sealer与AH Plus的凝固时间、流动性、pH值、阻射性、溶解度和体积变化;Bio-C Sealer凝固时间最短、流动性最高,但溶解度超出ISO 6876标准要求。

要点

  • Bio-C Sealer凝固时间最短、流动性最高,阻射性与体积变化与TotalFill BC Sealer相似。
  • Bio-C Sealer溶解度高于ISO 6876标准要求,临床应用需关注。
  • AH Plus阻射性最高,但流动性、pH值、溶解度和体积变化最低。

核心结论

  • Bio-C Sealer具有凝固时间短、可碱化、流动性和阻射性合适及体积变化低的特点,但溶解度高于ISO 6876标准要求。

研究设计与样本

  • 体外研究,依据ISO 6876标准评价凝固时间与流动性,并检测pH值、阻射性、溶解度与体积变化。
  • 比较Bio-C Sealer、TotalFill BC Sealer与AH Plus 3种根管封闭剂。
  • pH值在去离子水中储存1、7、14、21天后评估。
  • 溶解度与体积变化在蒸馏水浸泡30天后评估,分别用质量损失百分比与微计算机断层扫描成像评价。
  • 数据采用方差分析与Tukey检验,P < .05。

主要发现

  • TotalFill BC Sealer与Bio-C Sealer在阻射性、体积变化和pH值方面相似(P > .05)。
  • Bio-C Sealer凝固时间最短、流动性最高、溶解度最高(P < .05)。
  • AH Plus阻射性最高,流动性、pH值、溶解度和体积变化最低(P < .05)。

关键数值与推荐

  • 凝固时间与流动性依据ISO 6876标准评价。
  • Bio-C Sealer溶解度高于ISO 6876标准要求。
  • pH值评估时间点为去离子水储存1、7、14、21天。
  • 溶解度与体积变化评估时间点为蒸馏水浸泡30天。
  • 统计学显著性水平为P < .05。

临床怎么用

  • Bio-C Sealer凝固快、流动性好、可碱化且体积变化低,可作为硅酸钙基根管封闭剂的选择之一。
  • 其溶解度超出ISO 6876标准要求,临床使用时应关注长期封闭稳定性。

局限性

  • 本研究为体外理化性能评价,未涉及临床疗效或长期随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Calcium silicate-based materials have been proposed as root canal sealers for root canal treatment. The aim of this study was to evaluate the physicochemical properties of a new calcium silicate-based sealer (Bio-C Sealer; Angelus, PR, Brazil) compared with a calcium silicate endodontic sealer (TotalFill BC Sealer; FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) and an epoxy resin sealer (AH Plus; Dentsply DeTrey, Konstanz, Germany). METHODS: The setting time and flow were evaluated based on ISO 6876 standard. The pH value was evaluated after different time intervals of storage in deionized water (1, 7, 14, and 21 days). Radiopacity was evaluated by radiographic analysis in millimeters of aluminum. Solubility and volumetric change were evaluated after 30 days of immersion in distilled water. Solubility was assessed by mass loss (%), and volumetric change was evaluated by micro-computed tomographic imaging. The data were submitted to analysis of variance and Tukey statistical tests (P < .05). RESULTS: TotalFill BC Sealer and Bio-C Sealer were similar regarding radiopacity, volumetric change, and pH values (P > .05). Bio-C Sealer presented the shortest setting time and the highest flow and solubility (P < .05). AH Plus showed the highest radiopacity and the lowest flow, pH, solubility, and volumetric change (P < .05). CONCLUSIONS: Bio-C Sealer showed a short setting time, alkalinization ability, and adequate flow and radiopacity as well as low volumetric change. However, this sealer had higher solubility than the rates required by ISO 6876 standard.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Zordan-Bronzel CL, Esteves Torres FF, Tanomaru-Filho M, et al. Evaluation of Physicochemical Properties of a New Calcium Silicate-based Sealer, Bio-C Sealer. J Endod. 2019. PMID: 31447172. doi:10.1016/j.joen.2019.07.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。