文献速递牙体牙髓病

改良热充填单尖法根管充填技术研究

The single cone obturation technique with a modified warm filler.
PubMed 文献 · J Dent · 2019-08-17

本研究开发了一种结合热封闭剂与单尖牙胶的充填新方法,并评估其对复杂根管系统的适用性。研究测试了AH Plus、BioRoot RCS、GuttaFlow及原型封闭剂的流动性、薄膜厚度、凝固时间和阻射性,并用微计算机断层扫描评估了热改良前后单尖法充填的孔隙体积。结果显示加热影响封闭剂性能,单尖法可能不适用于复杂根管解剖,且AH Plus不宜承受高温。

要点

  • 加热会改变封闭剂的凝固时间、流动性、薄膜厚度和孔隙体积。
  • 单尖充填技术可能不适用于复杂根管解剖形态。
  • AH Plus不应承受高温,否则性能劣化且孔隙体积增加。

核心结论

  • 加热影响封闭剂性能及孔隙体积。
  • 单尖充填技术可能不适用于复杂根管解剖。
  • AH Plus不宜承受高温,因其性能劣化且孔隙体积增加。

研究设计与样本

  • 体外研究,测试AH Plus、BioRoot RCS、GuttaFlow及三硅酸钙基原型封闭剂。
  • 按ISO 6876(2012)在室温和100°C加热后测试封闭剂性能。
  • 用扫描电镜和能谱分析表征封闭剂,用微计算机断层扫描评估孔隙体积。

主要发现

  • 原型封闭剂虽设计类似BioRoot,但物理性能不同。
  • 所有测试封闭剂均受加热影响,物理性能发生变化。
  • 加热主要改变凝固时间、流动性、薄膜厚度和孔隙体积。

临床怎么用

  • 临床使用单尖法充填时需考虑根管解剖复杂性。
  • 避免对AH Plus施加高温以防止性能劣化和孔隙增加。
  • 热改良封闭剂时需注意其物理性能变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The aim of this study was to develop a new method of obturation by warm sealer in conjunction to single cone gutta-percha and evaluate the suitability of this technique to obturate complex root canal systems. METHODOLOGY: Three root canal sealers namely, AH Plus, BioRoot RCS, GuttaFlow and a prototype sealer composed of tricalcium silicate and 30% zirconium oxide mixed with water and water-soluble polymer were investigated. The sealers were tested for flow, film thickness, setting time and radiopacity following ISO 6876 (2012) recommendations at room temperature and following heat application at 100°C to change the sealer properties. All the test sealers were characterized by scanning electron microscopy and energy dispersive spectroscopy. The volume of voids when used with a single cone obturation technique both unmodified and modified by heat was evaluated using microcomputed tomography. RESULTS: Although the prototype sealer was designed to be similar to the BioRoot, its physical properties were found to be different. All sealers tested were affected by the heat and exhibited a change in the physical properties mainly the setting time, flow, film thickness and void volume. CONCLUSIONS: The application of heat affected the sealer properties and void volume. The single cone obturation technique may not be suitable for complex canal anatomy and furthermore, AH Plus should not be subjected to high temperatures as its properties deteriorate and void volume increases.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Heran J, Khalid S, Albaaj F, et al. The single cone obturation technique with a modified warm filler. J Dent. 2019. PMID: 31430509. doi:10.1016/j.jdent.2019.103181

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。