根管预备在体内不诱导牙本质微裂
本研究采用微计算机断层扫描技术,在体内评估对侧前磨牙分别用机用或手用ProTaper器械根管预备后牙本质微裂的发生情况。结果显示,机用组17,114个截面图像中未见微裂,手用组仅1个标本的116个截面(0.66%)见不完全微裂;结论认为两种器械体内预备均不导致牙本质微裂形成。
要点
- 机用ProTaper组17,114个截面图像中未观察到牙本质微裂。
- 手用ProTaper组仅1个标本的116/17,408个截面(0.66%)见不完全微裂。
- 阳性对照全部根尖三分之一见微裂,阴性对照未见微裂。
核心结论
- 采用机用或手用ProTaper器械对侧上下颌前磨牙进行根管预备,在体内不导致牙本质微裂形成。
研究设计与样本
- 分为阳性对照(n=6,诱导根微裂)、阴性对照(n=6,完整牙)及两个实验组(n=24)。
- 实验组分别采用ProTaper机用(PTR)或ProTaper手用(PTH)系统预备根管。
- 预备后以非创伤技术拔牙,并以17.18 μm分辨率进行微计算机断层扫描。
主要发现
- 共筛查43,361个根截面图像以检测牙本质微裂。
- 阳性对照组所有根在根尖三分之一显示微裂,阴性对照组标本未见微裂。
- PTR组分析17,114个截面图像,未观察到微裂。
- PTH组仅1个标本的17,408个截面中有116个(0.66%)见牙本质微裂。
- 这些不完全微裂从根外表面延伸至内层牙本质的牙本质厚度减少区域。
临床怎么用
- 对于需根管治疗的病例,机用或手用ProTaper器械预备在体内不增加牙本质微裂风险。
局限性
- 研究仅纳入因正畸拔除的前磨牙,结果可能不适用于其他牙位或感染根管。
- 样本量有限,实验组每组24颗牙。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This in vivo study aimed to evaluate the development of dentinal microcracks after root canal preparation of contralateral premolars with rotary or hand instruments using micro-computed tomographic technology. METHODS: Sixty contralateral intact maxillary and mandibular premolars in which extraction was indicated for orthodontic purposes were selected and distributed into positive (n = 6, teeth with induced root microcracks) and negative (n = 6, intact teeth) control groups as well as 2 experimental groups (n = 24) according to the instrumentation protocol: ProTaper rotary (PTR) or ProTaper hand (PTH) systems (Dentsply Maillefer, Ballaigues, Switzerland). After root canal preparation, teeth were extracted using an atraumatic technique and scanned at a resolution of 17.18 μm. A total of 43,361 cross-sectional images of the roots were screened for the presence of dentinal microcracks. The results were expressed as the percentage and number of root section images with microcracks for each group. RESULTS: All roots in the positive control group showed microcracks at the apical third, whereas no cracks were observed in the specimens of the negative control group. In the PTR group, 17,114 cross-sectional images were analyzed, and no microcrack was observed. In the PTH group, dentinal microcracks were observed in 116 of 17,408 cross-sectional slices (0.66%) of only 1 specimen. These incomplete microcracks extended from the external root surface into the inner root dentin at the area of reduced dentin thickness. CONCLUSIONS: Root canal instrumentation with PTR and PTH instruments of contralateral maxillary and mandibular premolars did not result in the formation of dentinal microcracks in vivo.
引用
- PradeepKumar AR, Shemesh H, Archana D, et al. Root Canal Preparation Does Not Induce Dentinal Microcracks In Vivo. J Endod. 2019. PMID: 31421915. doi:10.1016/j.joen.2019.06.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。