低初期稳定性种植体的回顾性病例系列结局评估
本回顾性病例系列纳入156例患者共169枚具有低初期稳定性(手动旋转)的种植体,随访至少34天、最长9.28年,评估种植体失败率及相关因素。结果显示7枚种植体失败,种植体水平累积生存率94.74%(95% CI: 89.11-97.50),患者水平94.33%(95% CI: 88.30-97.30);Kaplan-Meier分析显示种植体丢失仅见于复杂手术组(82枚中7枚丢失),简单手术组无丢失(87枚中0枚;p = 0.005)。结论认为在保证保护性无负荷愈合的前提下,低初期稳定性可能不影响种植体生存率或边缘骨水平变化。
要点
- 低初期稳定性种植体在保护性无负荷愈合下累积生存率可达94.74%。
- 种植体丢失仅发生在复杂手术组,简单手术组无失败(p = 0.005)。
- 低初期稳定性未必负面影响生存率或边缘骨水平变化。
核心结论
- 在回顾性研究局限内,低初期稳定性种植体若保证保护性无负荷愈合,可能不影响生存率或边缘骨水平变化。
研究设计与样本
- 回顾性病例系列,纳入156例患者共169枚具有低初期稳定性的种植体,随访最短34天、最长9.28年,遵循STROBE指南。
主要发现
- 7枚种植体在7例患者中失败,种植体水平累积生存率94.74%(95% CI: 89.11-97.50),患者水平94.33%(95% CI: 88.30-97.30)。
- Kaplan-Meier分析显示种植体丢失仅见于复杂手术组(82枚中7枚丢失),简单手术组无丢失(87枚中0枚;p = 0.005)。
关键数值与推荐
- 低初期稳定性定义为种植体在观察随访期内出现手动旋转。
- 复杂手术组种植体丢失7枚/82枚,简单手术组0枚/87枚,组间比较p = 0.005。
临床怎么用
- 对低初期稳定性种植体,应采用保护性、无负荷的愈合方案,并根据手术复杂程度加强随访。
局限性
- 回顾性研究设计存在固有局限,结果解释需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: There is a need of more studies on whether low primary implant stability would negatively influence the success of implant therapy. Therefore, this retrospective study analyses outcomes of implants placed with low primary stability and factors that may be related to implant failures. MATERIAL AND METHODS: This retrospective study included 156 patients, restored with 169 implants that presented manual rotation within an observed follow-up time of a minimum of 34 days and a maximum of 9.28 years. Descriptive statistics, survival analyses (life tables and Kaplan-Meier estimates) and radiographic assessment based on marginal bone level measurements were performed. This original study was adherent to STROBE guidelines. RESULTS: Seven implants failed in seven patients, rendering cumulative survival rates of 94.74% (95% CI: 89.11-97.50) and 94.33% (95% CI: 88.30-97.30) at implant and patient levels, respectively. Kaplan-Meier estimates showed implant loss was found only in advanced surgery group (7 implant loss in 82 implants) when compared with simple surgery group (no implant loss in 87 implants; p = 0.005). CONCLUSIONS: Within the limitations of this retrospective study, implant placement with low primary stability might not negatively affect either the survival rates or marginal bone level changes of implants provided that a protected and unloaded healing is guaranteed.
引用
- Lee KJ, Cha JK, Sanz-Martin I, et al. A retrospective case series evaluating the outcome of implants with low primary stability. Clin Oral Implants Res. 2019. PMID: 31168862. doi:10.1111/clr.13491
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。