文献速递口腔修复与种植

全数字化引导与徒手种植单颗牙种植体精度对比

The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery.
PubMed 文献 · J Clin Periodontol · 2019-07-19

一项随机对照临床试验比较静态计算机辅助种植手术(CAIS)与徒手种植在单牙缺失间隙中的种植体位置精度。结论为静态CAIS在单牙缺失间隙中提供的种植体位置精度高于徒手种植。

要点

  • 静态CAIS组角度偏差中位数2.8°,徒手组7.0°。
  • 静态CAIS组肩部偏差中位数0.9 mm,徒手组1.3 mm。
  • 静态CAIS组根尖偏差中位数1.2 mm,徒手组2.2 mm。

核心结论

  • 在单牙缺失间隙中,静态CAIS提供的种植体位置精度高于徒手种植。

研究设计与样本

  • 随机对照临床试验(RCT),纳入单牙缺失间隙且邻牙为天然牙的位点,随机分为静态CAIS组或徒手种植手术组。
  • 两组均基于锥形束CT(CBCT)和表面扫描数据进行数字化种植规划。
  • 静态CAIS组制作手术导板并用于全引导种植手术,徒手组以徒手方式植入种植体。
  • 术后CBCT用于9项测量,代表计划与实际种植体位置之间在角度、种植体肩部和根尖的偏差。

主要发现

  • 静态CAIS组角度偏差中位数(IQR)为2.8(2.6)°。
  • 静态CAIS组肩部偏差中位数(IQR)为0.9(0.8)mm。
  • 静态CAIS组根尖偏差中位数(IQR)为1.2(0.9)mm。
  • 徒手组角度偏差中位数(IQR)为7.0(7.0)°。
  • 徒手组肩部偏差中位数(IQR)为1.3(0.7)mm,根尖偏差中位数(IQR)为2.2(1.2)mm。

关键数值与推荐

  • 采用Mann-Whitney U检验,9项测量参数中6项差异有统计学意义(p < 0.05)。

临床怎么用

  • 对于单牙缺失间隙且邻牙为天然牙的种植病例,可优先考虑静态CAIS以提升种植体位置精度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: This randomized controlled clinical trial (RCT) aimed to compare the accuracy of implant positions between static computer-assisted implant surgery (CAIS) and freehand implant surgery in a single edentulous space. MATERIALS AND METHODS: Sites with single edentulous spaces and neighbouring natural teeth were randomized into static CAIS or freehand implant surgery groups. In both groups, digital implant planning was performed using data from cone beam computed tomography (CBCT) and surface scans. In the static CAIS group, a surgical guide was produced and used for fully guided implant surgery, while in the freehand group, the implants were placed in a freehand manner. Postoperative CBCT was used for nine measurements representing the deviations in angles, implant shoulders and apexes between planned and actual implant positions. RESULTS: Fifty-two patients received 60 single implants. The median (IQR) deviations in angles, shoulders and apexes were 2.8 (2.6)°, 0.9 (0.8) mm and 1.2 (0.9) mm, respectively, in the static CAIS group, and 7.0 (7.0)°, 1.3 (0.7) mm and 2.2 (1.2) mm, respectively, in the freehand group. Statistically significant differences were found in 6 out of nine measured parameters using Mann-Whitney U test (p < 0.05). CONCLUSION: Static CAIS provided more accuracy in implant positions than freehand placement in a single edentulous space.

来源:J Clin Periodontol,查看原文。版权归原作者所有。

引用

  1. Smitkarn P, Subbalekha K, Mattheos N, et al. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. J Clin Periodontol. 2019. PMID: 31241782. doi:10.1111/jcpe.13160

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。