文献速递牙体牙髓病

微创预备上颌第一磨牙根管充填质量:不同封闭剂比较

Quality of Root Filling after Obturation with Gutta-percha and 3 Different Sealers of Minimally Instrumented Root canals of the Maxillary First Molar.
PubMed 文献 · J Endod · 2019-06-08

研究比较微创预备并多声波清洁后,采用改良单尖法配合三种封闭剂充填上颌第一磨牙根管的质量。18颗牙随机分组,显微CT和光镜显示GuttaFlow Bioseal与GuttaFlow 2组充填材料平均体积高于MTA Fillapex组(P < .05),且GuttaFlow组截面无明显空隙。

要点

  • 微创预备至15/.04后多声波清洁可有效去除碎屑。
  • GuttaFlow Bioseal与GuttaFlow 2充填体积优于MTA Fillapex。
  • 改良单尖法配合GuttaFlow封闭剂可获得高质量充填。

核心结论

  • 微创预备上颌磨牙经多声波清洁后,改良单尖法配合GuttaFlow 2或GuttaFlow Bioseal封闭剂可获得高质量根管充填。

研究设计与样本

  • 离体牙实验:18颗上颌第一磨牙,根管预备至15/.04,5.25%次氯酸钠冲洗,GentleWave多声波清洁后分3组充填。

主要发现

  • 三组根管空间充填材料体积百分比为90%-99%。
  • GuttaFlow Bioseal和GuttaFlow 2组充填材料平均体积高于MTA Fillapex组(P < .05)。
  • 根尖、中、冠三分之一之间无显著差异。
  • GuttaFlow组截面图像无明显空隙或空洞。
  • 预备后189个根管三分之一中49个(25.9%)有硬组织碎屑;GentleWave清洁后仅4/63根管(6.3%)和4/189根管三分之一(2.1%)仍有碎屑。

临床怎么用

  • 对微创预备的上颌磨牙,可考虑多声波清洁后采用改良单尖法配合GuttaFlow系列封闭剂充填。
  • MTA Fillapex在该方案下充填体积较低,选择时需权衡。

局限性

  • 离体牙研究,样本量18颗,结果需临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of this study was to compare the quality of root fillings completed by a modified single-cone (MSC) technique with 3 different sealers after minimal instrumentation and multisonic cleaning of root canals of maxillary first molars. METHODS: Root canals of 18 maxillary first molars were instrumented to size 15/.04 taper using rotary files. Sodium hypochlorite 5.25% was used during instrumentation; the final cleaning was performed by the GentleWave System (Sonendo Inc, Laguna Hills, CA). The specimens were allocated into 3 groups and root filled by the MSC technique using a size fitted gutta-percha master cone and GuttaFlow Bioseal (Coltene Whaledent GmBH + Co KG, Langenau, Switzerland), GuttaFlow 2 (Coltene Whaledent GmBH + Co KG), and MTA Fillapex (Angelus Industria de Produtos Odontológicos S/A, Londrina, PR, Brazil) sealers. Micro-computed tomographic scans were obtained before and after instrumentation, post-GentleWave, and after obturation. Reconstructed images were analyzed for the volumetric percentage of filling materials. Mesiobuccal roots of the selected teeth were sectioned at 0.5-mm increments starting at the apex of the root. The cross sections were further examined using a light microscope. RESULTS: The 3 groups had 90%-99% of the canal space filled with the root filling material. The mean volume of the filling material was higher in the GuttaFlow Bioseal and GuttaFlow 2 groups than in the MTA Fillapex group (P < .05). There was no significant difference among the apical, middle, and coronal thirds. The cross-sectional images showed no obvious gaps or voids in the GuttaFlow groups. After instrumentation, 49 of the 189 canal thirds (25.9%) had hard tissue debris in the root canal system. After GentleWave cleaning, only 4 of 63 canals (6.3%) and 4 of the 189 canal thirds (2.1%) still had debris. CONCLUSIONS: The MSC method with GuttaFlow 2 and GuttaFlow Bioseal sealers after multisonic cleaning of minimally instrumented molar canals resulted in high-quality root fillings. Multisonic cleaning of minimally instrumented molars seems to be effective in debris removal.